摘要 高温高湿气候时,东南沿海核电厂重要厂用水泵房频发温度高报警或设备凝露问题,影响泵电机运行安全,降低核电厂冷源安全可靠性。因此,在不改变当前通风方式情况下,提出在泵房进风风室增加一种新风混风制冷机组进行空气温湿度处理的方法。机组采用两路新风,将经制冷除湿后的新风与外界新风混合。通过计算确定进风参数。该方法无需冷却所有新风,无需再热段,通过混风升温降低相对湿度,可以彻底解决所有工况下泵房环境温度、湿度超标问题,且兼顾经济性。 In high temperature and high humidity seasons,high temperature alarms or equipment condensations occur frequently in the southeast coastal nuclear power plants,which affects the safety of pump motor operation and reduces the safety and reliability of cold sources.A method of adding a mixed air refrigeration unit in the inlet air room is proposed,which does not change the current ventilation mode.The unit adopts two loops of fresh air,and mixes the fresh air after refrigerated and dehumidified with the fresh air outside.The inlet air parameters are determined by calculation.This method does not require to cool all fresh air and need no reheating segments,and it is to reduce the relative humidity by mixing air and increasing temperature,which is available to completely solve the problem of excessive temperature and humidity in the essential service water pump house under all working conditions,and take account of the economics.
作者 陈松平 张彩良 徐志军 CHEN Songping;ZHANG Cailiang;XU Zhijun(Suzhou Nuclear Power Research Institute Co.,Ltd.,Suzhou 215004;National Engineering Research Center for Nuclear Power Plant Safety&Reliability,Suzhou 215004;Fujian Ningde Nuclear power Co.,Ltd.,Ningde 355200)
出处 《电力安全技术》 2024年第1期66-70,共5页 Electric Safety Technology
关键词 重要厂用水泵 制冷机组 新风 混风 essential service water pump refrigerating unit fresh air mixed air
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部