摘要
本研究采用自制三维电极-电芬顿反应器,处理模拟的石油采出水。在保证出水水质的情况下,曝气量为0.8 L/min, pH值为3.5,电解电压为12 V,电解质投加浓度为5 g/L,极板间距为5 cm,系统耗电量较低,COD去除率达到85.9%,油脂去除率达到93.29%。三维电极-电芬顿耦合法对石油采出水处理效果好,无二次污染,运行简单,可在实际工程中得到推广应用。
This study used a self-made three-dimensional electrode-electro-fenton reactor to treat simulated petroleum produced water.While ensuring water quality,the aeration rate was 0.8 L/min,the pH was 3.5,the electrolysis voltage was 12 V,the electrolyte concentration was 5 g/L,and the electrode spacing was 5 cm.The system showed low power consumption,achieving COD removal rate of 85.9%and grease removal rate of 93.29%.The three-dimensional electrode-electro-fenton coupling method has good treatment effect on petroleum produced water,with no secondary pollution,simple operation,and potential for widespread application in practical engineering.
作者
刘济嘉
LIU Jijia(Liaoning Municipal Engineering Design and Research Institute Co.,Ltd.,Shenyang 110006,China)
出处
《供水技术》
2024年第1期17-21,共5页
Water Technology
基金
辽宁省高等学校杰出青年学者成长计划(LJQ2011057)。
关键词
三维电极
电芬顿
石油采出水
three-dimensional electrode
electric fenton
oil produced water