摘要 中国原子能科学研究院(CIAE)最新研制成功的紧凑型加速器质谱(AMS)装置,可用于^(14)C、^(129)I、^(239)Pu等多种核素测量。^(129)I是环境示踪常用的核素,^(129)I的测量对于该装置的推广应用至关重要。经过系统实验研究,建立了基于紧凑型AMS的^(129)I测量技术。^(129)I/^(127)I的测量灵敏度和精度分别达到1.5×10^(-14)与0.81%。结果表明:该紧凑型AMS装置对于^(129)I的测量已经达到国际先进水平,这也为^(129)I在核环境监测、海洋污染示踪等领域的应用研究奠定了坚实的基础。 A new compact accelerator mass spectrometer(AMS)facility,used for ^(14)C,^(129)I,^(239)Pu,etc.measurement,has been successfully established by China Institute of Atomic Energy(CIAE)recently.As ^(129)I is a commonly used nuclide for environmental tracing,the performance of 129I measurement is crucial for the applications of the facility.After systematic research,129I measurement technologies of the compact AMS has been established.The measurement sensitivity and the measurement accuracy of ^(129)I/^(127)I reached to 1.5×10^(-14) and 0.81%,respectively.The measurement results show that the compact AMS has reached the international advanced level and can lay the solid foundation for the application of ^(129)I in fields like nuclear environmental monitoring and marine pollution tracing.
作者 张文慧 赵庆章 何明 修诚利 李康宁 包轶文 郭巍 李建良 苏胜勇 游曲波 ZHANG Wenhui;ZHAO Qingzhang;HE Ming;XIU Chengli;LI Kangning;BAO Yiwen;GUO Wei;LI Jianliang;SU Shengyong;YOU Qubo(China Institute of Atomic Energy,Beijing 102413,China)
出处 《原子核物理评论》 CAS CSCD 北大核心 2023年第4期560-565,共6页 Nuclear Physics Review
关键词 ^(129)I 紧凑型AMS 测量技术 ^(129)I compact AMS measurement technology
  • 相关文献

参考文献2

二级参考文献13

  • 1WAGNER M, DITTRICH-HANNEN B, SYN- AL H A, et al. Increase of ^129I in the environ- ment[J]. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions With Materials and Atoms, 1996, 113 (1-4): 490-494.
  • 2REITHMEIER H, LAZAREV V, NOLTE E, et al. Anthropogenic ^129I in the atmosphere: Overview over major sources, transport proces- ses and deposition pattern[J]. Science of the To- tal Environment, 2010, 408(21): 5 052-5 064.
  • 3ZHOU W, HOU X, CHEN N, et al. Prelimina- ry study of radioisotope ^129I application in China using Xi' an accelerator mass spectrometer[J]. INCS News, 2010, 25: 8-23.
  • 4LOPEZ-GUTIERREZ J, GARCIA-LEON M, SCHNABEL C, et al. Determination of ^129I in atmospheric samples by accelerator mass spec- trometry[J]. Applied Radiation and Isotopes, 1999, 51(3): 315-322.
  • 5SANTOS F J, LPEZ-GUTIRREZ J M, CHAMIZO E, et al. Advances on the determina- tion of atmospheric i291 by accelerator mass spec- trometry (AMS)[J]. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions With Materials and Atoms, 2006, 249(1-2) : 772-775.
  • 6MIYAKE Y, MATSUZAKI H, FUJIWARA T, et al. Isotopic ratio of radioactive iodine (^129 I/ ^131 I) released from Fukushima Daiichi NPP acci- dent[J]. Geochemical Journal, 2012, 46 (4) : 327-333.
  • 7HOU X, POVINEC P P, ZHANG L, et al. Iodine-129 in seawater offshore Fukushima.. Dis- tribution, inorganic speciation, sources, and Budget[J]. Environmental Science & Technolo- gy, 2013, 47(7): 3 091-3 098.
  • 8常印忠,刘龙波,王世联,刘蜀疆,王军,万可友,吴艳敏,陈占营,樊元庆,李奇,贾怀茂,张新军.PMS-800大流量大气颗粒物采样器的研制[J].辐射防护,2011,31(1):39-44. 被引量:11
  • 9蒋崧生,何明,谢运棉,姜山,武绍勇.环境中人造^(129)I的AMS方法测定[J].质谱学报,1999,20(3):127-128. 被引量:3
  • 10姜山,董克君,何明.超灵敏加速器质谱技术进展及应用[J].岩矿测试,2012,31(1):7-23. 被引量:10

共引文献10

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部