期刊文献+

基于暂态响应时间分析与暂稳态模式识别的锁相环参数自适应方法 被引量:1

Phase-locked loop parameter adaptive method based on transient response time analysis and transient steady-state pattern recognition
下载PDF
导出
摘要 锁相环的设计对保障交流网络中设备安全运行有着重要意义,锁相环实现方法与参数设计对锁相环的响应时间、抗扰能力等控制特性起到重要影响。本文通过结合小信号频域模型与大信号状态空间模型,分析同步坐标系锁相环的暂稳态响应特性,得出各参数设计对于锁相环控制特性的影响;在理论分析基础上,提出了基于响应时间与暂稳态模式识别的锁相环参数自适应框架。仿真与实验结果验证了所提出的参数自适应方法可以通过实现参数动态调节,达到对锁相环暂态快速响应与稳态抗扰的设计要求。 The design of phase-locked loops is of great importance to ensure the safety of equipment in AC power grid operation.In this paper,the transient and steady-state response characteristics of the synchronous reference frame are studied.Based on response time analysis and transient steady-state pattern recognition,an adaptive framework for phase-locked loop parameters is proposed.The parameters are tuned dynamically to make the phase-locked loop to meet the design requirements of transient fast response and steady-state immunity,and the performance is verified by simulation and experiments.
作者 于艇 贾文阁 杜冰心 孙辉 代宇琦 雷万钧 YU Ting;JIA Wen’ge;DU Bingxin;SUN Hui;DAI Yuqi;LEI Wanjun(China Nuclear Power Design Co.,Ltd.,Shenzhen 518000,China;School of Electrical Engineering,Xi’an Jiaotong University,Xi’an 710049,China)
出处 《电工电能新技术》 CSCD 北大核心 2024年第3期31-40,共10页 Advanced Technology of Electrical Engineering and Energy
基金 国家重点研发计划项目(2018YFB0905805)。
关键词 锁相环 弱电网 低通滤波器 自适应控制 同步坐标系 phase-locked loop weak grid low-pass filter adaptive control synchronous reference frame
  • 相关文献

参考文献6

二级参考文献68

共引文献96

同被引文献10

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;