摘要 抽水蓄能机组转动部分的动态异常状况的排查和消缺一直是机组调试及维护过程中的难点。本文主要记录了某电站调试中遇到的机组转动部分对地绝缘下降的问题。通过屏柜因素的排除,机组机械部分的合理拆分以及动静态结合排查缺陷的方式,将此问题圆满解决。文中主要对分析过程和处理过程进行了较详细的描述。 The investigation and elimination of the dynamic abnormal condition of the rotating part of the pumped-storage unit is always the difficulty in the commissioning and maintenance of the unit.The problem of insulation decline of unit rotation part to ground encountered in the commissioning of a power station is mainly recorded in this paper.Through the way of elimination of protective panel factors,the reasonable split of the mechanical part of the unit and the combined dynamic and static inspection of defects,the problem has successfully been solved.The analysis process and processing process are described in detail in thus paper.
作者 邵丽娟 关一第 杨雷 SHAO Lijuan;GUAN Yidi;YANG Lei(Harbin Electric Machinery Company Limited,Harbin 150040,China)
出处 《上海大中型电机》 2024年第1期39-41,53,共4页 Shanghai Medium and Large Electrical Machines
关键词 抽水蓄能机组 转子动态异常状况 发电电动机保护屏柜 接地电阻 接触电阻 转子绝缘 Pumped storage unit Dynamic abnormality of rotor protection screen cabinet Ground resistance Contact resistance Insulation of rotor