摘要 本文针对定距角锥棱镜长度标准器的校准问题进行研究,阐述该装置的构成,提出一种光学顶点直接瞄准与快速装调的方案,并与激光干涉测长装置搭配使用。经实践检验,该装置可实现光学顶点、中心的迅速瞄准与定位,使角锥长度标准器更加精准可靠,快速准确地完成瞄准与校准,且结果精准可靠。 In this paper,the calibration of the length standard of fixed-distance pyramid prism is studied.The structure of the device is described first,and then a scheme of direct aiming and rapid adjustment of optical vertices is proposed,which is used in conjunction with the laser interference length measuring device.According to the research results,the device can realize the rapid aiming and positioning of the optical vertex and center,which makes the pyramid length standard more accurate and reliable,completes the aiming and calibration quickly and accurately,and the results are accurate and reliable.
作者 李振宇 LI Zhenyu(Xinzhou Comprehensive Inspection Testing Center Xinzhou City,Xinzhou Shanxi 034000)
出处 《中国科技纵横》 2024年第2期91-93,共3页 China Science & Technology Overview
关键词 角锥棱镜 激光干涉测长 直接瞄准 校准技术 pyramid prism laser interference length measurement direct aiming calibration technology
  • 相关文献

参考文献7

二级参考文献42

  • 1倪思方.激光跟踪仪校准中的测量不确定度评估[J].工业计量,2012,22(S1):92-96. 被引量:6
  • 2Pieles H, et al. Interferometric Equipment for Precise Measurements of Line Standards and their Thermal Expansion [ J ]. MAPAN-Journal of Metrology Society of India, 1995, 10(2):65-73.
  • 3高宏堂 叶孝佑 孙双花 等.空气弹簧隔振平台自动调平控制的研究.计量学报,2009,30(5):107-110.
  • 4叶孝佑 高宏堂 邹玲丁 等.2m比长仪纳米级高精度刻线自动瞄准系统.计量学报,2010,31(6):107-111.
  • 5叶孝佑,高宏堂,邹玲丁,等.2m激光干涉比长仪研制[R].中国计量科学研究院SJG-0301,2010.
  • 6高宏堂 叶孝佑 解菁 等.2m比长仪动态校准位移传感器的研究.计量学报,2010,31(6):116-119.
  • 7天津大学精密仪器系精密机械教研,精密机械零件,1979年
  • 8光学仪器设计手册组,光学仪器设计手册,1972年
  • 9迟桂纯,激光在计量测试技术中的应用,1994年
  • 10张国维,精密仪器电路,1986年

共引文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部