期刊文献+

ICP-AES法测定低钇混合稀土组分 被引量:2

Determination of Composition in Minor Yttrium Rare Earth Mixtures by ICP-AES
下载PDF
导出
摘要 本文拟定ICP-AES直接测定低钇混合稀土组分的方法,确定了适宜的测定条件。方法准确、快速、简便。样品分析结果与X-荧光光谱法及导数分光光度法相符。各元素测定相对标准偏差为1.4~3.3%。 A method for direct determination of composition in minor yttrium rare earth mixtures by ICP-AES has been developed. This method is more accurate, simple and rapid. Some main working parameters of ICP were measured. The results obtained are comparable with those of X-ray fluorescence spectroscopy and derivative spectrophotomety in other laboratories. The accuracy has been tested by sample No 4 with satisfactory results. The relative standard deviations were in the range 1.4-3.3%.
作者 袁甫 綦文娣 裴蔼丽 Yuan Fu;Qi Wendi;Pei Aili(Changchun Institute of Applied Chemistry,Academia Sinica)
出处 《岩矿测试》 CAS 1988年第3期227-229,I0011,共4页 Rock and Mineral Analysis
  • 相关文献

同被引文献429

引证文献2

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部