摘要 分析了PVC干燥输送系统压力高的具体原因,进行了相应的技术改进,从而提高了干燥输送系统运行的稳定性,降低了设备维修成本和维修人员劳动强度。 The specific reasons for the high pressure in a PVC drying and conveying system were an-alyzed,and corresponding technical improvements were made.Thus,the operation stability of the drying and conveying system was improved,and equipment maintenance costs and the labor intensity of mainte-nance personnel were reduced.
作者 岳蕊祥 杜欢 YUE Ruixiang;DU Huan(Chemical Branch,Shaanxi Beiyuan Chemical Group Co.,Ltd.,Yulin 719319,China)
出处 《聚氯乙烯》 CAS 2024年第2期13-15,共3页 Polyvinyl Chloride
关键词 PVC 干燥 输送系统 罗茨风机 空气悬浮风机 压力 下料器 PVC drying transportation system Roots blower air suspension fan pressure un-loader