期刊文献+

基于高光谱技术的灵芝孢子粉破壁率快速检测方法研究

A Rapid,Hyperspectral-based Method for Determining Sporoderm-broken Rate of Ganoderma Lucidum Spore Powder
原文传递
导出
摘要 目的 利用高光谱技术结合化学计量学建立灵芝孢子粉破壁率快速无损的检测方法。方法 采集不同破壁率灵芝孢子粉样品的高光谱图像,选定感兴趣区域后计算获得各样品可见-短波近红外波段(397~1 004 nm)内的光谱数据;比较运用标准正态变量变换、多元散射矫正、Savitsky-Golay(SG)平滑、小波变换、SG平滑+标准正态变量变换及SG平滑+多元散射矫正6种光谱预处理方法,竞争性自适应重加权、连续投影算法、无信息变量选择、最小角回归、遗传算法5种特征波段提取方法以及偏最小二乘法、支持向量回归、极限学习机回归、多层感知机回归及LightGBM回归5种算法所建立的定量校正模型预测性能。结果 获得最优预测性能的算法组合为SG平滑+竞争性自适应重加权特征波段选择+偏最小二乘;基于该算法组合建立的定量校正模型在破壁率区间为90%~100%的灵芝孢子粉样品预测集决定系数为0.868 2,均方根误差为0.011 7;将选定的最优算法组合应用于构建样品破壁率区间为0~100%的定量校正模型,计算测试集决定系数为0.973 1,均方根误差为0.049 3,表现出良好的泛化能力。结论 所建立的定量检测模型可以实现对灵芝孢子粉破壁率的快速、无损检测,为破壁灵芝孢子粉及其产品的质量控制提供技术支撑。 OBJECTIVE To establish a rapid nondestructive detection method for the sporoderm-broken rate of Ganoderma lucidum spore powder by hyperspectral technology combined with chemometrics.METHODS Hyperspectral images of Ganoderma lucidum spore powder samples with different sporoderm-broken rates were collected,and spectral data in the visible-shortwave near-infrared band(397-1004 nm)range of each sample were calculated after selecting the region of interest.Compared 6 spectral preprocessing methods[standard normal variable transformation,multivariate scattering correction,Savitsky-Golay(SG)smoothing,wavelet transform,SG smoothing+standard normal variable transformation,and SG smoothing+multivariate scattering correction],5 characteristic band extraction methods(competitive adaptive reweighting,successive projections algorithm,uninformative variables elimination,least angle regression,and genetic algorithm),and 5 algorithms(partial least squares regression,support vector regression,extreme learning machine,multilayer perceptron,and LightGBM)for constructing quantitative correction models to predicts performance.RESULTS The optimal combination was SG smoothing+competitive adaptive reweighted feature band selection+partial least squares.The quantitative correction model established based on the algorithm combination achieved a prediction set coefficient of 0.8682,and a root mean square error of 0.0117 for Ganoderma lucidum spore powder samples with a sporoderm-broken rate range of 90%-100%.The selected optimal algorithm combination was applied to construct a quantitative correction model with a sporoderm-broken rate range of 0-100%,the coefficient of determination for the test set was 0.9731 and the root mean square error was 0.0493,showing good generalization ability.CONCLUSION The established quantitative detection model can realize the rapid and non-destructive detection of the sporoderm-broken rate of Ganoderma lucidum spore powder,which provides technical support for the quality control of Ganoderma lucidum spore powder and its products.
作者 潘在晨 仲怿 方玲 祁哲晨 徐靖 梁宗锁 李振皓 PAN Zaichen;ZHONG Yi;FANG Ling;QI Zhechen;XU Jing;LIANG Zongsuo;LI Zhenhao(Zhejiang Provincial Key Laboratory of Plant Secondary Metabolism Regulation,College of Life Sciences and Medicine,Zhejiang Sci-Tech University,Hangzhou 310018,China;Zhejiang Shouxiangu Institute of Plant Medicine,Hangzhou 310012,China;Zhejiang Engineering Research Center of Rare Medicinal Plants,Wuyi 321200,China)
出处 《中国现代应用药学》 CAS CSCD 北大核心 2024年第6期760-766,共7页 Chinese Journal of Modern Applied Pharmacy
基金 浙江省农业(食用菌)新品种选育重大科技专项(2021C02073) 浙江省重点农业企业研究院项目(2017Y20001)。
关键词 高光谱成像 灵芝孢子粉 破壁率 化学计量学 定量校正模型 hyperspectral imaging Ganoderma lucidum spore powder sporoderm-broken rate chemometrics quantitative calibration model
  • 相关文献

参考文献20

二级参考文献254

共引文献541

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部