对一套安装光伏直流水泵的横双排分离式全玻璃真空管太阳能热水系统的热性能进行试验,分析了光伏直流水泵对太阳能热水器热性能的影响.结果表明,与常规的自然循环系统相比,光伏直流水泵会使太阳能热水系统的日有用得热量减少0.77 MJ/m^(2),热效率降低4.5%,但贮热水箱内水温分布较均匀,贮热水箱上、下层热水的平均温差仅为1.46℃.
A set of horizontal double-row separated all-glass evacuated tube solar water heating system installed with photovoltaic DC pump was tested to study and analyze the effect of photovoltaic DC pump on the thermal performance of the system.The results showed that,compared with the conventional natural circulation system,the PV DC pump reduced the daily useful heat gain of the solar water heating system by 0.77 MJ/m^(2),and the thermal efficiency was reduced by 4.5%,but the distribution of the water temperature in the water storage tank was more uniform,and the average temperature difference between the upper and lower hot water storage tanks was only 1.46℃.
作者
覃雅致
吴良豪
付鸿凯
李如剑
高文峰
QIN Yazhi;WU Lianghao;FU Hongkai;Li Rujian;GAO Wenfeng(School of Energy and Environment Science,Yunnan Normal University,Kunming 650500,China;Key Laboratory of Rural Energy Engineering of Yunnan,Kunming 650500,China;Yunnan Huoying Solar Water Heater Co.,Ltd.,Kunming 650206,China)
出处
《云南师范大学学报(自然科学版)》
2024年第2期31-33,共3页
Journal of Yunnan Normal University:Natural Sciences Edition
基金
国家自然科学基金资助项目(51969032,12262036)。
关键词
光伏直流水泵
太阳能热水器
热性能
运行特性
Photovoltaic DC water pump
Solar water heating system
Thermal performance
Operating characteristics