迈瑞CX-9000全自动凝血分析仪性能评估

Performance evaluation of Mindray CX-9000 automatic coagulation analyzer
下载PDF
导出
摘要 目的:对迈瑞CX-9000全自动凝血分析仪的性能进行验证评估。方法:参照行业标准和国家标准,通过凝血酶原时间(prothrombin time,PT)、活化部分凝血活酶时间(activated partial thromboplastin time,APTT)、纤维蛋白原(fibrinogen,FIB)、凝血酶时间(thrombin time,TT)、D-二聚体5个凝血常规检查项目对迈瑞CX-9000全自动凝血分析仪进行性能验证,评估该仪器的精密度、准确度、线性范围、携带污染率及参考区间能否满足临床需求。结果:5个凝血常规检查项目的批内精密度变异系数(coefficient of variation,CV)均<3%,日间精密度CV均<5%,准确度相对偏差在±10%以内。FIB的线性回归方程斜率k为1.0060,相关系数r为0.9993,D-二聚体的线性回归方程k为1.0132,r为0.9975,线性良好。样本浓度携带污染率CR1为4.6%,项目携带污染率CR2均<2%,参考区间R值均为100%,均符合行业标准要求,验证通过。结论:迈瑞CX-9000全自动凝血分析仪是一款精密度好、准确度高、线性范围宽、携带污染率低的检测系统,能够满足临床需求。 Objective To verify and evaluate the performance of Mindray CX-9000 automatic coagulation analyzer.Methods Myriad CX-9000 automatic coagulation analyzer had its performance validated and evaluated by five routine coagulation tests with reference to the industry including standard prothrombin time(PT),activated partial thromboplastin time(APTT),fibrino-gen(FIB),thrombin time(TT)and D-dimer,so as to clarity whether the analyzer meets the clinical requirements in terms of precision,accuracy,linear range,carry-over and reference interval.Results The five routine coagulation tests had the intra-batch precision CVs lower than 3%,the inter-day precision CVs lower than 5%and the relative deviations of the accuracies within±10%.The slope k of the linear regression equation was 1.0060 for FIB and 1.0132 for D-dimer,and the correlation coefficient r was 0.9993 for FIB and 0.9975 for D-dimer,which showed high linearity.The carry-over rate of sample concen-tration(CR1)was 4.6%,and the carry-over rate between test items(CR2)was lower than 2%;the R value of the reference interval was 100%;the requirements of industrial standards were met.Conclusion Mindray CX-9000 automatic coagulation analyzer gains advantages in precision,accuracy,linear range and carry-over,and is worthy promoting clinically.
作者 郭家权 韦炅 李苗 李坷坷 刘明 GUO Jia-quan;WEI Jiong;LI Miao;LI Ke-ke;LIU Ming(Department of Clinical Laboratory,Hainan Provincial People's Hospital,Haikou 570311,China)
出处 《医疗卫生装备》 CAS 2024年第2期58-61,共4页 Chinese Medical Equipment Journal
关键词 迈瑞CX-9000全自动凝血分析仪 精密度 准确度 携带污染率 线性范围 参考区间 性能评估 Mindray CX-9000 automatic coagulation analyzer precision accuracy carry-over linear range reference interval performance evaluation
  • 相关文献

参考文献4

二级参考文献27

  • 1中国合格评定国家认可委员会.CNAS--CL02:2008,医学实验室质量和能力认可准则[S].2007.
  • 2王治国.临床检验方法确认与性能评价[M].北京:人民卫生出版社,2009:12.
  • 3Clinical and Laboratory Standards Institute. Evaluationof precision performance of quantitative measurementmeth- ods[ S]. EP5-A2, CLSI, 2004.
  • 4Clinical and Laboratory Standards Institute. User demon- stration of performance for precision and accuracy[S]- EP15-A2, CLSI, 2004.
  • 5Clinical and Laboratory Standards Institute. Evaluationof the linearity of quantitative measurement p rocedures [S]. EP6--A2, CLSI, 2003.
  • 6Clinical and Laboratory Standards Institute. Interference testing in clinical chemistry [ S]. EP7 -- A2, CLSI, 2005.
  • 7Clinical and Laboratory Standards Institute. How to de- fine and determine reference intervals in the clinical labo- ratory[S]. C28--A2, CLSI, 2000.
  • 8杨栋梁,杨晋荣.血浆D-二聚体水平检测对临床血栓性疾病阴性预测值的意义评价[J].实用医技杂志,2011,18(3):274-275. 被引量:10
  • 9王洪亚,张捷.建立检验项目参考区间的探讨[J].临床检验杂志,2011,29(7):548-550. 被引量:44
  • 10苏荣,叶桂样,罗娜,杨延斌,蒋开平,张劲丰.乙型肝炎病毒E抗原检测方法性能的初步评价[J].实验与检验医学,2013,31(1):21-23. 被引量:5

共引文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部