摘要
总结了当前输电线路铁塔塔脚锈蚀特征、塔脚锈蚀的危害及锈蚀机理,并提出了铁塔塔脚锈蚀防治措施,从根源上消除铁塔锈蚀安全隐患,提升输电线路安全运行水平,以期为相关人员提供参考。
The characteristics of tower foot corrosion,the damage and the corrosion mechanism of tower foot corrosion are summarized,and the prevention measures against tower foot rust are put forward,which eliminates the potential safety risks of tower corrosion ultimately,improves the safe operation level of transmission lines and is available to offer reference for relevant personnel.