期刊文献+

某320 MW电厂锅炉主燃料跳闸保护回路问题及优化

Problem and Optimization of the Main Fuel Trip Protection Circuit for 320 MW Power Plant Boiler
下载PDF
导出
摘要 锅炉主燃料跳闸(MFT)是火电厂锅炉的重要保护回路,其主要作用是在发生某种特殊情况时,该控制回路可以迅速切断进入炉膛的燃料,避免事故发生。目前,大部分火电厂的回路设计基本上满足相关标准的要求,但是个别机组的回路仍存在保护拒动的风险。阐述某电厂在检修期间发现的回路问题,利用机组检修期重新设计MFT保护回路并完成具体实施,进一步提高MFT保护回路的可靠性。 The boiler main fuel trip(MFT) is an important protection circuit for thermal power plant boilers.Its significance lies in the fact that when a special situation occurs,this control circuit can quickly cut off the fuel entering the furnace to avoid accidents.At present,the circuit design of most thermal power plants basically meets the requirements of relevant standards,but there is still a risk of protection failure in the circuits of individual units.Elaborate on the circuit problems discovered during the maintenance period of a certain power plant,redesign the MFT protection circuit during the unit maintenance period,and complete the specific implementation to further improve the reliability of the MFT protection circuit.
作者 李健 LI jian(North China Electric Power Research Institute of China Datang Group Science and Technology Research Institute Co.,Ltd.,Beijing 100040,China)
出处 《自动化应用》 2024年第6期45-47,共3页 Automation Application
关键词 主燃料跳闸 火电厂锅炉 保护回路 MFT thermal power plant boiler protection circuit
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部