摘要
目前我国多联机变频空调机组均采用全年性能系数(APF)替代IPLV作为评价指标。基于现有多联变频空调器的调节范围广的特点,指出了现有APF中对于选择性试验即低温制冷工况实测时,会出现不符合实际的情况,利用实测数据和理论分析产生的原因,水平展开,并给出了针对实测的改进建议。
At present,the annual coefficient of performance(APF)is used instead of IPLV as the evaluation index of multi-online inverter air conditioning units in China.Based on the characteristics of the wide adjustment range of the existing multi-inverter air conditioner,it is pointed out that the existing APF will not conform to the actual situation when the selective test,that is,the low-temperature refrigeration condition is measured,and the reasons for the measured data and theoretical analysis are used to expand horizontally,and the improvement suggestions for the actual measurement are given.
出处
《日用电器》
2024年第3期37-42,52,共7页
ELECTRICAL APPLIANCES
关键词
变频多联机组
选择性试验
低温制冷实测
全年性能系数(APF)
制冷季节耗电量(CSTE)
frequency-conversional multi-connected air-conditioning system
choice tests
low-temperature operation test(cooling)
annual performance factor(APF)
cooling seasonal total energy(CSTE)