通过对4个铝合金晶粒度测定标准进行对比分析,明确了各标准间的一致性和差异性。结合GB/T 3246.1—2012、GB/T 3246.2—2012两个标准,对铝合金晶粒度实际测定过程中存在的问题进行了讨论、分析,对晶粒度测试试样的前处理方法、浸蚀方法及结果判定标准给出了建议,为同类测定问题提供参考解决方案,有利于铝合金晶粒度测试方法的不断改进。
By comparing and analyzing four aluminium alloy grain size testing standards,the consistency and difference between the standards were clarified.Based on the two standards of GB/T 3246.1-2012 and GB/T 3246.2-2012,this paper discusses and analyz⁃es the problems existing in the actual measurement process of aluminium alloy grain size.Suggestions are given for the pre-treatment method,etching method,and result judgment standard of grain size test samples,providing reference solutions for similar testing problems and promoting the continuous improvement of aluminum alloy grain size testing methods.
作者
袁圣
张思平
辛荣
李政龙
陈小谦
YUAN Sheng;ZHANG Siping;XIN Rong;LI Zhenglong;CHEN Xiaoqian(Southwest Aluminium(Group)Co.,Ltd.,Chongqing 401326,China)
出处
《铝加工》
CAS
2024年第2期52-56,共5页
Aluminium Fabrication
关键词
铝合金
晶粒
晶粒度
标准比对
aluminum alloy
grain
grain size
standard comparison