摘要
主要阐述了什么是SEMI F47电压瞬降,SEMI F47的标准曲线及测试特性规范,如何预防电压瞬降的技术措施,通过一系列措施的改进、参数设置、线路改进等使设备具有应对电压瞬降的能力,保证设备正常运行。
This paper mainly describes what is SEMI F47 voltage sag immunity,SEMI F47 standard curve and test characteristic specification;how to prevent voltage sag immunity technical measures;through a series of measures improving,parameter setting and line improvement,the equipment has the ability to cope with voltage sag immunity and ensure the normal operation of the equipment.
作者
姜慧慧
高智刚
Jiang Huihui;Gao Zhigang(CETC Fenghua Information Equipment Co.,Ltd.,Taiyuan Shanxi 030024,China)
出处
《山西电子技术》
2024年第2期120-122,共3页
Shanxi Electronic Technology