摘要
为了避免空冷发电机在高盐雾环境中运行时盐雾进入发电机内部,导致发电机内部结构件发生腐蚀,影响发电机的寿命和性能,开发了一种空冷发电机防盐雾装置。漏气量试验结果表明,该装置的密封性满足性能要求,由此验证了该装置结构设计的合理性。
In order to avoid the salt spray entering the generator when the air-cooled generator is running in a high salt spray environment,resulting in corrosion of the internal structural parts of the generator and affecting the life and performance of the generator,an anti-salt spray device for air-cooled generators is developed.The air leakage test results show that the sealing performance of the device meets the performance requirements,thus,verifying the rationality of the structural design of the device.
作者
杨保哲
YANG Baozhe(Shanghai Electric Power Generation Equipment Co.,Ltd.Generator Plant,200240)
出处
《电机技术》
2024年第2期6-9,共4页
Electrical Machinery Technology
关键词
腐蚀
防盐雾装置
空冷发电机
corrosion
anti-salt spray device
aircooled generator