摘要
为快速检测甲烷氯化物生产过程反应液中氯单质含量,以碘化钾为显色剂,将反应液中氯单质还原成氯离子,碘离子氧化成碘单质,通过目视比色法测定。通过建立标准色阶,考察显色剂用量,显色时间等对结果的影响。结果表明,该方法具有较高的准确性,加标回收率在96.8%~103.3%,检出限为1 mg/L,操作简单,可满足生产紧急需要。
To quickly detect the content of chlorine element in the reaction solution of methane chloride production process,potassium iodide is used as a chromogenic agent to reduce chlorine element in the reaction solution to chloride ions,and iodine ions are oxidized to iodine element,which is determined by visual colorimetry.By establishing a standard color scale,it investigates the effects of reagent dosage,color development time,and other factors on the results.The results show that the method has high accuracy,with a spiked recovery rate of 96.8%to 103.3%,a detection limit of 1 mg/L,simple operation,and can meet urgent production needs.
作者
陈彩琴
邵红才
吴云竹
傅永斌
CHEN Caiqin;SHAO Hongcai;WU Yunzhu;FU Yongbin(Zhejiang Quhua Fluoride Chemical Co.Ltd.,Quzhou,Zhejiang 324004)
出处
《化工生产与技术》
CAS
2024年第2期37-39,I0005,共4页
Chemical Production and Technology
关键词
甲烷氯化物
氯单质
比色法
methane chloride
chlorine
colorimetry