某企业醋酸乙烯装置脱丁烯醛塔自运行以来腐蚀问题严重,造成异常和非计划停工较多,严重影响装置长周期安全稳定运行。该研究通过工艺物料分析和实验室模拟试验,研究脱丁烯醛塔的腐蚀规律,分析腐蚀原因并提出防腐措施,为装置的平稳运行提供了保障。
Severe corrosion problems occurred in the debutenal tower of a vinyl acetate unit,resulting in frequent abnormal and unplanned shutdowns,which seriously affected the long-term safe and stable operation of the plant.Through the process material analysis and laboratory simulation test,the corrosion mechanism of debutenal tower was studied,the causes of corrosion were ana-lyzed and the anti-corrosion measures were put forward to provide guarantee for the smooth operation of the unit.
作者
武新宁
刘旭霞
刘希武
WU Xinning;LIU Xuxia;LIU Xiwu(SINOPEC Great Wall Energy and Chemical(Ningxia)Co.,Ltd.,Yinchuan 750411,China;SEG Luoyang R&D Center ofTechnology,Luoyang 471003,China)
出处
《石油化工腐蚀与防护》
CAS
2024年第2期14-21,共8页
Corrosion & Protection In Petrochemical Industry
基金
中国石化科技开发项目“羰基合成醋酸-醋酸乙烯-聚乙烯醇联合装置腐蚀成因与控制技术研究”(CHG21115)。
关键词
醋酸乙烯
脱丁烯醛塔
腐蚀
vinyl acetate
debutenal tower
corrosion