摘要 采用抗坏血酸还原氯金酸制备纳米金,在钴离子的存在下,半胱氨酸诱导纳米金团聚,溶液颜色由红色变为蓝色,据此建立一种半胱氨酸测定新方法。讨论了纳米金-钴离子比色探针的制备条件,探究了测定半胱氨酸的实验条件。结果表明:纳米金-钴离子比色探针测定半胱氨酸的最佳反应时间为20 min、缓冲溶液p H为3.0,该方法测定半胱氨酸的线性回归方程为A_(725)/A_(520)=0.3965 C+0.0133(C单位为μM),R^(2)=0.9882,线性范围为1×10^(-7)~1×10^(-6)mol/L,方法检出限为2.2×10^(-8)mol/L。采用标准加入法对健康人的尿样进行回收率测定,回收率为92.8%~95.8%。文中创建了一种简便测定半胱氨酸的方法。 In this paper,ascorbic acid was used to reduce chlorauric acid to prepare gold nanoparticles.In the presence of cobalt ion,cysteine induced gold nanoparticles to agglomerate and the color of the solution changed from red to blue.A new method for determination of cysteine was established.The preparation conditions of gold-cobalt ion colorimetric probe were discussed and the experimental conditions for determination of cysteine were investigated.The results show that:The optimal reaction time and p H of buffer solution were 20 min and 3.0 respectively.The linear regression equation for the determination of cysteine was A_(725)/A_(520)=0.3965C+0.0133(C:μM),R^(2)=0.9882.The linear range was 1×10^(-7)mol/L to 1×10^(-6)mol/L,and the detection limit was 2.2×10^(-8)mol/L.The recovery rate of urine samples from healthy people was determined by standard addition method,and the recovery rate was92.8%~95.8%.A simple method for the determination of cysteine was developed.
作者 徐永智 毛丽惠 刘雯雯 卜欣欣 徐康远 张伟 XU Yongzhi;MAO Lihui;LIU Wenwen;BU Xinxin;XU Kangyuan;ZHANG Wei(College of Science and Technology,Xinyang College,Xinyang 464000,China)
出处 《广州化学》 CAS 2024年第2期73-77,I0004,共6页 Guangzhou Chemistry
基金 2022年度信阳学院大学生科研项目(2022-DXSLYB-009)。
关键词 纳米金 钴离子 比色法 半胱氨酸 测定 nanometer gold cobalt ion colorimetry cysteine determination
  • 相关文献

参考文献2

二级参考文献5

共引文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部