摘要
针对桥巩水电站5号机组盘车时转轮出现反转的情况,通过开展机组稳定性试验,分析试验结果以及机组动平衡,得出机组盘车时转轮反转及运行振动偏大的原因,为机组安全稳定运行提供依据。
In view of the reversal of the runner during the turning of the Unit 5 in Qiaogong Hydropower Station the stability test of the unit is conducted the test results and the dynamic balance of the unit are analyzed and the reasons for the reversal of the runner and the large vibration of the unit are obtained which provides a basis for the safe and stable operation of the unit.
作者
廖灿坤
蒙辉
黎灵宗
侯焕
何能镇
LIAO Cankun;MENG Hui;LI Lingzong;HOU Huan;HE Nengzhen(Guangxi Guineng Technology Development Co.Ltd.Nanning 530007, China;Guangxi Guangtou Qiaogong Energy Development Co.Ltd.Laibin 546100 ,China)
出处
《红水河》
2024年第2期133-138,共6页
Hongshui River
关键词
盘车
转轮反转
稳定性试验
振动
摆度
不平衡力
turning
runner reversal
stability test
vibration
swing
unbalance force