期刊文献+

配筋UHPC预制管混凝土组合柱轴压试验

An experimental study on concrete filled reinforced UHPC tube composite columns under axial compression
下载PDF
导出
摘要 为研究超高性能混凝土(UHPC)相对于钢筋混凝土(RC)柱的基本受力性能,以UHPC预制管配箍率和长/细比为试验参数,对6根配筋UHPC预制管混凝土组合柱进行轴压试验.结果表明,与RC柱和UHPC预制空心柱相比,配筋UHPC预制管混凝土组合柱能明显改善RC柱的压溃现象和UHPC的脆性特征.为更好地发挥共同受力作用,应让紧箍效应提早出现.采用ABAQUS软件建立组合柱的有限元计算模型,分析表明UHPC强度、径/厚比、 UHPC配箍率、长/细比是影响配筋UHPC预制管混凝土组合柱轴压试验结果的重要参数. In order to study the basic mechanical properties of ultra-high-performance concrete(UHPC)on reinforced concrete columns,axial compression tests were carried out on 6 reinforced UHPC precast concrete composite columns with the stirrup ratio and slenderness ratio as test parameters.The test results showed that,compared with ordinary reinforced concrete(RC)columns and UHPC precast hollow columns,the reinforced UHPC precast concrete composite columns could significantly improve the crushing phenomenon of RC columns and the brittleness characteristics of UHPC.In order to better play the role of joint force,the hoop effect should appear early.A finite element calculation model of the composite column was established via the ABAQUS program.According to the finite element parameter analysis,UHPC strength,diameter-thickness ratio,UHPC stirrup ratio and slenderness ratio were important parameters affecting the axial compression test of reinforced UHPC precast concrete composite columns.
作者 欧智菁 陈玮悦 颜建煌 曹磊 OU Zhi-jing;CHEN Wei-yue;YAN Jian-huang;CAO Lei(Key Laboratory of Advanced Technology and Informatization in Civil Engineering of Fujian Province,Fujian University of Technology,Fuzhou 350118,China)
出处 《兰州大学学报(自然科学版)》 CAS CSCD 北大核心 2024年第2期253-261,共9页 Journal of Lanzhou University(Natural Sciences)
基金 国家自然科学基金项目(51878172) 福建省自然科学基金项目(2022J01929)。
关键词 超高性能混凝土 预制管 组合柱 静力试验 有限元 ultra-high performance concrete precast tube composite column static test finite element
  • 相关文献

参考文献7

二级参考文献451

共引文献599

相关作者

内容加载中请稍等...

相关机构