摘要
本文针对600MW超超临界机组省煤器入口集箱管座裂纹,从多方面进行原因分析,并建模计算验证,提出改进措施,保障锅炉的安全运行。
In this article,crack of the tube socket for economizer inlet header in some 600MW supercritical boiler is described.The reasons are analyzed from various aspects,then modeling calculation and verification and design improvement measure are proposed,which ensures the safe operation of boiler.
作者
王明亮
WANG Mingliang(Harbin Boiler Company Limited,Harbin 150046,China)
出处
《锅炉制造》
2024年第3期13-14,共2页
Boiler Manufacturing
关键词
超超临界机组
裂纹
建模计算
优化设计
supercritical power plant
crack
modeling calculation
optimized design