期刊文献+

一起智能电能表焊锡残留问题的处理及监造对策

Handling and Supervision Measures for Solder Residue in an Intelligent Energy Meter
下载PDF
导出
摘要 随着国家对智能电能表产品大量应用,国网要求保证整表使用寿命≥16年,为了保证产品质量,部分省电力公司委托监造单位实施驻厂监造,监造组加强了制造厂内产品工艺质量的见证管理。以一起智能电能表PCB板手工焊锡残留问题为例,从实践的角度,探讨了智能电能表产品PCB板焊接质量监造问题的发现、处理及其监造对策。以期为类似项目产品监造提供借鉴和参考。 With the widespread application of smart energy meter products by the country,State Grid requires that the service life of the entire meter be greater than or equal to 16 years.In order to ensure product quality,some provincial power companies have entrusted supervision units to implement on-site supervision.The supervision team has strengthened the witness management of product process quality in the manufacturing plant.Taking the issue of manual soldering residue on a smart energy meter PCB board as an example,this paper explores the discovery,handling,and supervision strategies of the quality supervision problem of PCB board soldering in smart energy meter products from a practical perspective,in order to provide reference and inspiration for product supervision in similar projects.
作者 周文辉 Zhou Wenhui(Hunan Xiangneng Electric Power Equipment Supervision Co.,Ltd.,Changsha 410004)
出处 《设备监理》 2024年第2期12-15,共4页 Plant Engineering Consultants
关键词 电能表 监造 焊锡残留 监造对策 Electricity meter Manufacture supervision Solder residue Supervision measures