摘要 换相失败是基于电网换相换流器的特高压直流输电系统中最常见的故障类型之一。近年来新投运的混合级联特高压直流输电系统的逆变侧仍包含电网换相换流器,因此换相失败无法避免。首先,在分析电网换相换流器触发调节过程的基础上,明确了换相失败控制的投入时刻是影响换相失败抑制效果的关键因素;进一步地,结合白鹤滩—江苏混合级联特高压直流输电受端的结构特点和接入交流系统方式,分析了混合级联拓扑下的换相失败抑制新思路;最后,提出可充分利用逆变侧电压观测点增加、模块化多电平变换器所连接母线的电压响应更为灵敏的特点,来加快换相失败控制的投入速度,提升系统的换相失败抑制性能。基于PSCAD/EMTDC仿真平台验证了该分析的正确性。 Commutation failure is one of the most common types of failures in line commutated converter based ultra-high voltage direct current(LCC-UHVDC)system.In recent years,the inverter side of the newly installed hybrid-cascaded UHVDC system still contains LCC,so the commutation failure is unavoidable.Based on the analysis of trigger regulation process of LCC,it is clear that the input time of commutation failure control is the key factor affecting the effect of commutation failure suppression.Further,according to the structure characteristics of receiving end of Baihetan-Jiangsu hybrid-cascaded UHVDC and the access mode of AC system,a new idea of commutating failure suppression under hybrid-cascaded topology is analyzed.It is proposed to fully utilize the increased voltage observation points of inverter,and enhance the sensitivity of bus voltage response connected to modular multilevel converter(MMC),which can accelerate the startup speed of commutation failure control and the suppression performance of commutation failure.The correctness of analysis is verified by PSCAD/EMTDC simulation platform.
作者 刘磊 李小鹏 滕予非 LIU Lei;LI Xiaopeng;TENG Yufei(State Grid Sichuan Electric Power Research Institute,Chengdu 610041,Sichuan,China)
出处 《四川电力技术》 2024年第2期1-4,69,共5页 Sichuan Electric Power Technology
基金 国网四川省电力公司科技项目(B3199722000K)。
关键词 特高压直流输电 混合级联 换相失败 控制策略 UHVDC hybrid-cascaded commutation failure control strategy
  • 相关文献

参考文献6

二级参考文献99

共引文献251

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部