期刊文献+

无创非自动测量血压计检定过程中泄露水银的收集处理方法

Method for Collection and Treatment of Mercury Leakage During the Verification of Sphygmomanometer Without Invasive and Automatic Measurement
下载PDF
导出
摘要 水银血压计是监控血压的重要仪器设备,按照规定每半年需进行一次检定,在检定和维护过程中很容易出现水银泄漏问题,对检定人员的身体健康造成一定的危害。介绍了回收和处理泄漏水银的几种方法,采用物理沉降方法对其进行分离和封闭,采用化学方法对其进行无害化处理。根据收集、沉淀、反应、储存、循环和集中处理等环节,研制出一种原理简单、操作简便的快速收集和集中处理设备,能够有效降低环境、水质及土壤污染,避免对检验人员造成伤害,是一种高效的无害化处理设备。 Mercury sphygmomanometer is an important instrument for monitoring human blood pressure.According to regulations,it needs to be verified once half a year.During calibration and maintenance,it is easy to encounter mercury leakage problems,causing certain harm to the physical health of calibration personnel.The study mainly introduces several methods for recovering and treating leaked mercury.It is separated and sealed by physical sedimentation,and received innocent treatment by chemical process.A simple and easy to operation equipment for rapid collection and centralized treatment has been developed based on collection,precipitation,reaction,storage,circulation and centralized treatment.It can effectively reduce pollution to the environment,water quality,and soil,and prevent harm to the health of inspectors.It is an efficient and harmless treatment equipment.
作者 石武清 Shi Wuqing(Huayuan County Quality Inspection and Metrological Verification Center,Xiangxizhou 416400,China)
出处 《黑龙江科学》 2024年第10期151-152,155,共3页 Heilongjiang Science
关键词 无创非自动测量血压计 硫黄 泄露水银 无害化处置 Non-invasive and non automatic measurement of blood pressure monitor Sulfur Leakage of mercury Harmless processing
  • 相关文献

参考文献3

二级参考文献6

  • 1中华人民共和国计量法[S].1985.
  • 2JJG270-2008,血压计和血压表检定规程[S].
  • 3黄传原,屠海文.血压计及其检定[M].北京.中国计量出版社,2008,8.
  • 4国家质量技术监督局计量司编.JJF1001-1998,通用计量术语及定义解释[S].北京:中国计量出版社,2000.
  • 5将思敬,姚士春.压力计量[M].北京,中国计量出版社,1991.
  • 6中华人民共和国计量法实施细则[S].1987.