饱和器后煤气中H_(2)S含量升高的原因及解决措施

Cause and solution of H_(2)S increase in COG after saturator
下载PDF
导出
摘要 分析了焦炉煤气中H_(2)S含量在脱硫工段达标,但在饱和器及终冷塔后再次升高的原因以及采取的措施。将一种新型高效除尘捕雾装置成功运用到脱硫工序,不仅使煤气中H2S含量稳定达标,对硫铵工序长期连续稳定运行也具有至关重要的作用。 This paper analyzes the reasons why the content of H_(2)S in coke oven gas(COG)after saturator and final cooling tower increases again after reachin g standard in desulfurization unit.Measures that have been taken are analyz ed as well.Introduction is given to a new type of high-efficiency dus t and mist catcher that has been successfully applied to the desulfurization unit,which not only stabilizes the content of H_(2)S in COG up to standard,but plays an important role in long-term continuous and stable operation of ammonium sulfate process.
作者 李金平 曹伟 李维民 卓润华 Li Jinping;Cao Wei;Li Weimin;Zhuo Runhua(Pingdingshan Dongxin Coking Co.,Ltd.,Pingdingshan 467000,China)
出处 《燃料与化工》 CAS 2024年第3期46-48,共3页 Fuel & Chemical Processes
关键词 焦炉煤气 H_(2)S超标 解决措施 COG H_(2)S exceeding standard limit Solution