摘要
采用一种新型线性聚能装药结构,研究了不同炸高时线性聚能装药射流对混凝土墙体的毁伤效应。数值模拟发现,药型罩锥角为80°与50°时,能较好地避免拉断现象。得到了线性聚能装药结构的射流头部速度、侵彻深度随炸高的变化规律。炸高为60 mm时,最佳侵彻深度达130.6 mm。对炸高为60 mm与100 mm时的线性聚能装药进行试验研究。结果表明,炸高100 mm时,侵彻深度达到125.0 mm,与仿真结果吻合较好。验证了该线性聚能装药结构对混凝土墙体的毁伤效果较好。可为线性聚能装药结构的设计与试验研究提供参考。
A new type of linear shaped charge structure was adopted to study the influence of stand-off on the da-mage of linear shaped charge jet on concrete walls.In numerical simulations,it has found that when the cone angles of the shaped charge are 80°and 50°,it can effectively avoid the phenomenon of pulling and breaking.The variation law of jet head velocity and penetration depth with stand-off for linear shaped charge structure was obtained.The optimal penetration depth reaches 130.6 mm when the stand-off is 60 mm.Experimental study was conducted on linear shaped charge with stand-off of 60 mm and 100 mm.The results show that when the stand-off is 100 mm,the penetration depth reaches 125.0 mm,which is in good agreement with the simulation results.The linear shaped charge structure has been verified to have a good destructive effect on concrete walls.It can provide reference for the design and experimental research of linear shaped charge structures.
作者
陈思羽
黄正祥
CHEN Siyu;HUANG Zhengxiang(School of Science,National University of Defense Technology,Hu nan Changsha,410073;School of Chemical Engineering,Nanjing University of Science and Technology,Jiangsu Nanjing,210094)
出处
《爆破器材》
CAS
CSCD
北大核心
2024年第3期43-47,共5页
Explosive Materials
关键词
混凝土墙体
线性聚能装药
拉断现象
药型罩锥角
炸高
concrete wall
linear shaped charge
pull-off phenomenon
cone angle of liner
stand-off