期刊文献+

粮食自动取制样系统及其清洁性能的验证

Verification of the Grain Automatic Sampling System and Its Cleaning Performance
下载PDF
导出
摘要 为提高进口散装船运粮食样品采集及制备的效率,研发一套粮食自动取制样系统。通过荧光PCR方法对该粮食自动取制样系统制备的粮食样品进行转基因定性检测试验,结果表明粮食样品没有出现转基因和非转基因成分交叉污染的情况,说明粮食自动取制样系统的清洁性能符合检测要求。 In order to improve the efficiency of sample collection and preparation of imported bulk shipments of grain,an automatic sampling system was developed.Transgenic qualitative test was carried out on the grain samples prepared by the automatic sampling system by fluorescent PCR method.The results showed that there was no cross-contamination of transgenic and non-transgenic components in the grain samples,indicating that the cleaning performance of the automatic grain sampling and preparation system meets the testing requirements.
作者 刘姣姣 陈萍 吴小瑶 黄挺 罗广志 LIU Jiaojiao;CHEN Ping;WU Xiaoyao;HUANG Ting;LUO Guangzhi(Guangzhou Customs Technology Center,Guangzhou 510623,China;Nansha Customs,Guangzhou 511458,China)
出处 《现代食品》 2024年第7期19-22,共4页 Modern Food
基金 广州海关科研项目(2021GZCK08)。
关键词 粮食自动取制样系统 样品交叉污染 清洁性能 grain automatic sampling system sample cross contamination cleaning performance