摘要 为了完善凹面光栅衍射效率测试仪的研制,需要对凹面光栅衍射效率测试仪的光学(成像)系统进行设计和分析。根据仪器光学系统的设计要求,分别对Ⅲ型凹面光栅和Ⅳ型凹面光栅组成的光学系统进行设计和模拟,给出了各自光学系统的像面点列图和实际光线追迹数据。设计结果表明,仪器光学系统的出射光斑最大宽度为0.72 mm,最大高度为7.54 mm;通过适当选择探测器的规格和尺寸,可以确保出射光通量没有损失。进而保证了仪器光学系统的测量准确性。 In order to finish the research of the instrument for testing diffraction efficiency of concave grating,the optical system design and simulation of the concave grating is need to be done on the instrument.According to the design requirement,the design and simulation on the optical system of the type Ⅲ concave grating and the typeⅣconcave grating has been done respectively,the spot diagram of the image surface and the results of real ray trace was given.As a result,the maximum width of the exit spot is 0.72 mm and the maximum height of the exit spot is 7.54 mm in the optical system of the instrument,though selected the size and the specification of the detector properly,the exit luminous flux would not be lost.Which guarantee the testing precision of the optical system of the instrument.
作者 寇婕婷 汪浩鹏 易拥洁 吴鹏程 Kou Jieting;Wang Haopeng;Yi Yongjie;Wu Pengcheng(United Microelectronics Center,Chongqing,China)
出处 《科学技术创新》 2024年第12期74-77,共4页 Scientific and Technological Innovation
关键词 凹面光栅 衍射效率 光学设计 结果分析 concave grating diffraction efficiency optical design results analysis
  • 相关文献

参考文献4

二级参考文献43

  • 1李朝明,吴建宏,唐敏学.平场全息凹面光栅的设计[J].激光杂志,2005,26(2):57-58. 被引量:14
  • 2李锡善,蒋海英,蒋安民.光学玻璃的色散特性测量及近似计算方法的讨论[J].光学学报,1995,15(2):206-211. 被引量:8
  • 3杨广立,冯飞,熊斌,王跃林.微机械光读出红外成像阵列器件机械特性对其性能的影响[J].光学精密工程,2007,15(5):699-705. 被引量:5
  • 4陈吉武,林中,孟庆华.平场全息凹面光栅的设计[J].光学精密工程,1997,5(1):96-103. 被引量:6
  • 5李林,安连生.Computer Aided Optical Design Theory and Application(计算机辅助光学设计理论与应用).Beijing:Defense Industry Press(北京:国防工业出版社),2005.
  • 6Zemax Optical Design Program User's Guide. January, 2006.
  • 7PETERSEN H. BESSY technical report T1329[R]. Berlin:BESSY, 1980.
  • 8PIMPALE A V,DESHPANDE S K,BHIDE V G. Design considerations for the rotation'of a plane premirror of a monochromator for reflecting synchrotron radiation onto the same spot of the dispersing grating of the XUV beamline[J]. Applied Optics, 1991,30(13) : 1591-1594.
  • 9RIEMER F, TORGE R. Bessy SX-700 UHV monochromator: design features and kinematic concept[J]. Nucl. Instrum. Methods, 1983,208 (1-3) : 313-314.
  • 10PETERSEN H, JUNG C, HELLWING C, et al.. Review of plane grating focusing for soft x-ray monochromators[J]. Rev. Sic. Instrum. , 1995,66 (1):1-14.

共引文献59

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部