摘要
在对S31608换热管在冷氢化装置中的失效原因进行研究分析,结果表明换热管失效主要为应力和腐蚀性介质Cl共同作用引起的应力腐蚀开裂而失效。
This article studies and analyzes the failure causes of S31608 heat exchange tubes in the cold hydrogenation device.The results indicate that the failure of heat exchange tubes is mainly caused by the stress corrosion cracking caused by the joint action of stress and corrosive medium Cl.
作者
柯曾鹏
陈维平
葛蒙
KE Zengpeng;CHEN Weiping;GE Meng
出处
《化工设计通讯》
CAS
2024年第5期61-63,共3页
Chemical Engineering Design Communications
关键词
四氯化硅
冷氢化
换热管
失效
应力腐蚀
tetrachlorosilicon
cold hydrogenation
heat exchange tubes
invalidation