摘要 Humid air turbine cycle(HAT)has potential of electrical efficiencies comparable to combined cycle,with lower investment cost and NO_(x) emission.The typical heat exchanger network of HAT consists of intercooler(if there is),aftercooler,recuperator,economizer and humidifier,which brings higher efficiency but makes the system more complex.To simplify HAT layout,a novel humidifier concept is proposed by integrating the aftercooler into traditional counter-current humidifier.Based on this concept,a one-dimensional model including pressure drop and exergy calculation is established to distinguish the thermodynamic and hydrodynamic characteristics,and then the structural parameters,such as the number of rows and columns,tube diameter,pitch and type for a micro HAT are identified.The results show that the aftercool-humidifier plays the same role as original aftercooler and humidifier,and can match the in-tube air,out-tube air and water stream well with lower volume.In the case of micro HAT cycle,the volume of heat and mass transfer area can be reduced by 47%compared with traditional design.The major thermal resistance occurred in the convection heat transfer process inside the tube;however,using enhanced tube cannot effectively improve the compactness of device.
出处 《Journal of Thermal Science》 SCIE EI CAS CSCD 2024年第3期951-969,共19页 热科学学报(英文版)
基金 financial support by National Science and Technology Major Project(2017-I-0009-0010)to this research work。