摘要 对浙江某1000 MW机组燃煤锅炉电除尘器螺旋线断裂问题进行了采样和分析,包括宏观形貌、断口SEM形貌、断口能谱、金相和安装问题进行了分析,结果表明:螺旋线化学成分符合ASTMA959-11的技术要求,断口上覆盖的异物中S元素质量分数高达27.34%,螺旋线断裂的主要原因是运行环境中S元素高,次要原因是安装不规范。在此基础上,在燃煤含硫量低于2.5%的烟气下电除尘器螺旋线使用316L以上材料并改进安装要求后,在多个工程上应用后,未发生螺旋线断裂问题。 Electrostatic precipitator(ESP)is the main technology of coal-fired flue gas dust treatment.Spiral wire has the advantages of uniform current density and high operating voltage,and is the best discharge electrode applied in the final electric field.However,with the wide application of the low-low temperature ESP technology,the fracture failure of the helix occurs frequently under the low-temperature working condition.Sampling and analysis were conducted on the spiral line fracture of the electrostatic precipitator of a 1000 MW unit in Zhejiang Province,including macrosco-pic,fracture SEM,fracture energy spectrum,metallographic and installation problem analysis,the results show that the chemical composition of the spiral wire meets the technical requirements of ASTM A959-11,and the content of S element in the foreign objects covered on the fracture surface is as high as 27.34%.The main reason for the fracture of spiral wire is the high S element in the operating environment,and the secondary reason is that the installation is not standardized.On this basis,after using 316L or above materials and improving installation requirements for the spiral line of the electrostatic precipitator in flue gas with a sulfur content lower than 2.5%in coal combustion,it has been applied in multiple projects without any spiral line fracture problem.
作者 赵海宝 杜宇江 何毓忠 梁江 ZHAO Haibao;DU Yujiang;HE Yuzhong;LIANG Jiang(Key Laboratory of Coal-fired Flue Gas Purification Equipment Research of Zhejiang Province,Zhuji Zhejiang 311800,China;不详)
出处 《工业安全与环保》 2024年第6期64-68,共5页 Industrial Safety and Environmental Protection
基金 国家重点研发计划项目(2022YFC3701501)。
关键词 燃煤机组 螺旋线 电除尘 断裂 SEM形貌分析 coal-fired units spiral line electrostatic precipitation fracture SEM analysis
  • 相关文献

参考文献6

二级参考文献21

  • 1王俊民.电除尘工程手册[M].北京:中国标准出版社.2008.
  • 2郦建国,龙辉,郦祝海,等.低低温电除尘技术研究及应用[C]//第十五届中国电除尘学术会议论文集.2013.
  • 3YOSHIO Nakayama,SATOSHI Nakamura,YASUHIRO Takeuchi,et al.MHI high efficiency system-proven technology for mul.
  • 4MASAMI Kato,TADASHI Tanaka,YASUKI Nishimura,et al.Method and system for handling exhaust gas in a boiler:USA.
  • 5土屋喜重,川西好光,大西召一,等.Very cold electrostatic technology of advanced flue gas treatment system for co.
  • 6柳生隆志,土屋喜重,大西召一,等.Recent electrostatic precipitation technology[J].三菱重工技报,1996,33(1):69-73.
  • 7Development and demonstration of waste heat integration with solvent process for more efficient CO2 removal f.
  • 8柴田宪司,三重野光博,山本卓也.電気集麈方法[P].三菱重工技报.2000.
  • 9TOSHIAKI Misaka,YOSHIHIKO Mochizuki.Recent application and running cost of moving electrode type electrostati.
  • 10STEPHENL Francis,ANDREAS Back,PER Johansson.Reduction of rapping losses to improve ESP performance[C]//11th I.

共引文献129

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部