摘要 本文提出了一种关于复合绝缘子高温硫化硅橡胶在综合老化作用下的使用寿命和剩余寿命的分析方法。通过分析新品绝缘子硅橡胶在综合老化试验中拉伸强度的退变趋势和五级修硅橡胶的初始拉伸强度,评估其新品硅橡胶使用寿命和五级修硅橡胶的剩余寿命。实验表明,新品硅橡胶在综合老化条件下退变到五级修的加速因子为18.64;进一步评估新品伞裙的使用寿命为14.8年,五级修绝缘子伞裙的剩余寿命为6.8年。后续可为绝缘子的检修策略优化提供数据支撑。 This paper presents a method for analyzing the service life and residual life of high temperature vulcanized silicone rubber for composite insulators under comprehensive aging.By analyzing the degeneration trend of tensile strength and the initial tensile strength of the five-stage repaired silicone rubber,the service life of the new insulator silicone rubber and the remaining life of the five-stage repaired silicone rubber were evaluated.The experiment proved that,under the condition of comprehensive aging,the acceleration factor of new silicone rubber degenerative to the fifth grade repair is 18.64;It is further evaluated that the service life of the new umbrella skirt is 14.8 years,and the remaining life of the fifth class insulator repair umbrella skirt is 6.8 years.The follow-up can provide data support for insulator maintenance strategy optimization.
作者 肖明明 吴悠 蒋洁 杨博 XIAO Ming-ming;WU You;JIANG Jie;YANG Bo(CRRC Tangshan Locomotive and Rolling Stock Co.,Ltd.,Tangshan 063000)
出处 《环境技术》 2024年第5期171-175,共5页 Environmental Technology
关键词 高温硫化硅橡胶 综合老化 加速因子 使用寿命 剩余寿命 high-temperature vulcanized silicone rubber comprehensive aging accelerated factor working life residual life
  • 相关文献

参考文献2

二级参考文献37

  • 1陈晓春,郑敏聪,李建华.合成绝缘子硅橡胶伞群材料的老化特性及其红外光谱研究[J].中国电机工程学报,2012,32(S1):57-62. 被引量:34
  • 2谢绍国,曾新,朱福海.塑料实验室光源曝露试验方法——第1部分:通则[J].合成材料老化与应用,1995,24(1):14-19. 被引量:1
  • 3张锐,吴光亚.500kV交、直流输电线路鸟啄损坏复合绝缘子统计和分析[J].电瓷避雷器,2005(5):8-11. 被引量:13
  • 4殷禹,梁曦东,李庆锋,宿志一,范建斌,史梓男.复合绝缘子的人工加速老化试验[J].电网技术,2006,30(12):69-74. 被引量:33
  • 5LIANG Xidong, WANG Shaowu, FAN Ju, et al. Developmentcomposite insulators in China[J]. IEEE Transactions on Die- ctrics and Electrical Insulation, 1999, 6(5): 586-594.
  • 6CIGRE TF 33.04.07. Natural and artificial ageing and pollution test of polymeric insulators [ R]. Paris, France: CIGRE bro- chure 142, 1999.
  • 7Schneider H M, Guidi W W, Brunham J T. Accelerated ageing and flashover tests on 138 kV non-ceramic insulators[J]. IEEE Transaction on Power Delivery, 1993, 6(5) : 325-336.
  • 8Schneider H M, Guidi W W, Slocik J P, et al. Accelerated age- ing facility for full scale 500 kV non-ceramic insulators[C]//The 8th International Symposium on High Voltage Engineering. Yo kohama, Japan: IEEE, 1993.
  • 9Garcia R W S, Torres M S, Silva F R, Natural and accelerated ageing of composite insulators[C]// 1998 IEEE International Symposium on Electrical Insulation. Virginia, United States: IEEE, 1998: 329-333.
  • 10Sundararajan R, Graves J, Monanmmed A. Performance evalu- ation of polymeric insulators aged in lab and field[C]/// 1999 Conference on Electrical Insulation and Dielectric Phenomena. Texas, United States: [s. n.], 1999: 695-698.

共引文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部