期刊文献+

无机房电梯设置紧急电动运行装置的可行性与必要性探讨

Discussing on Feasibility and Necessity of Roomless Elevator with Emergency Electric Running Device
下载PDF
导出
摘要 本文以一起检验过程中无机房电梯未设置紧急电动运行装置的情况为切入点,提出该情形下电梯不能满足各种载荷工况下安全及时救援的问题,通过对问题产生原因的详细分析,从电气控制原理方面提出了改进措施。最后,依据国家相关标准讨论了无机房电梯设置紧急电动运行装置的可行性与必要性,并提出建议。 In this paper,taking room-less elevator without emergency electric running device as an example,safe and timely rescue under various conditions cannot be met in this case,the reason of this problem is analyzed,and the improvement measures are put forward from the electrical control principle.Finally,the feasibility and necessity of room-less elevator with emergency electric running device are discussed according to the relevant national standards and some suggestions are put forward.
作者 白朝中 陈永贤 寇雪峰 Bai Chaozhong;Chen Yongxian;Kou Xuefeng(Chengdu Institute of Special Equipment Inspection and Testing,Chengdu,Sichuan 610200)
出处 《西部特种设备》 2024年第2期69-73,共5页 Western Special Equipment
基金 一种电梯盘车力测量方法及装置的研究(编号:CTKJ2024030500015)。
关键词 无机房电梯 紧急电动 救援 Room-less elevator Emergency electric Rescue
  • 相关文献

参考文献3

二级参考文献3

共引文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部