摘要 本文介绍了一种波长宽、响应快的静态体三维显示系统,包括显示介质、控制系统及激光系统三部分。实验中,选取具有双频上转换效应的NaYF4∶Er@NaGdF4∶Yb@NaYF4∶Er纳米晶溶液作为显示介质。控制系统选用1024×768的数字微镜显示器(DMD)及扫描振镜对红外激光进行投影,使用成像光学软件将立体图像的二维切片转换为DMD/扫描振镜的控制信号。激光系统选用1550 nm和850 nm的红外激光,用适当的光学元件调整光束和光路。最终在纳米晶的环己烷溶液中(1 mmol/mL)以30×1024×768的分辨率实现了绿色(532 nm)三维图像体的快速扫描,图像无闪烁、深度线索自然、可360°观看。该显示系统对材料性能要求不高,搭建方便,显示效果明显,为上转换材料在三维显示领域的初步研究及大尺寸体三维显示技术的探究提供了参考。 Objective The static volumetric 3D display technology displays 3D objects by volume pixels in 3D space,presenting real stereoscopic images.It can provide physiological and psychological depth clues for human visual systems to perceive 3D objects and can meet all-around observation needs.Additionally,it is the most likely 3D display technology to achieve high spatial resolution,multi-angle,and simultaneous observation of multiple people,real-time interaction,and large size.Among them,the static volume 3D display technology based on dual beam addressing has attracted much attention due to its unique advantages such as fine voxel,high spatial resolution,easy realization of full-color display,and meanwhile the image is no shaking and does not require auxiliary equipment(such as glasses)to view.By employing the energy of two infrared photons to pump a material into an excited energy level,the electrons in the excited energy level will transition to a lower energy level and produce visible light,which is an effective way to achieve dual-beam addressing.The material that can implement this luminescence process is also known as the two-step two-frequency(TSTF)up-conversion luminescence(UCL)material,and it can have great potential applications in static volumetric 3D display technology due to its rapid response,high contrast,and high color purity.Despite this,the material has received few reports in volumetric 3D display applications because of its low UCL efficiency and small display volume.Additionally,some literature focuses on the properties of materials,with less introduction of 3D display systems.The above two points greatly limit the application and research interest of the 3D volume display of TSTF UCL materials.Thus,we develop a 3D imaging system based on the TSTF UCL mechanism of rare earth ions,and meanwhile build a projection imaging optical path based on digital optical processing(DLP)and a line laser shaping optical path based on scanning galvanometer and cylindrical mirror.The display system is based on the TSTF UCL technology,which employs a dual infrared laser excitation,and adopts the digital micromirror display(DMD)and scanning galvanometer to achieve rapid scanning of image volume at high resolution.It has lower material performance requirements and cost,and more simple method than dual DLP imaging mode.This system is very suitable for the preliminary study of the stereoscopic display effect of TSTF UCL materials and also provides an effective idea for the imaging schemes of other addressing media materials.Additionally,the TSTF UCL material utilized for the display is a cyclohexane solution of core-shell NaYF4∶0.5%Er@NaGdF4∶2%Yb@NaYF4∶1%Er(NYF@NGF@NYF)nanocrystals,which has great potential for large-scale imaging.Methods We present a static volumetric 3D display system with wide wavelength and fast response,which includes three parts of display medium,control system,and laser system.In the experiment,nanocrystals NaYF4∶Er@NaGdF4∶Yb@NaYF4∶Er with dual-step dual-frequency up-conversion ability are selected as imaging medium.The control system employs 1024×768 DMD and scanning galvanometer to project the infrared laser.By the appropriate design of imaging optical software,the two-dimensional slice of the stereoscopic image is converted into the control signal of the DMD/scanning galvanometer.The laser system adopts 1550 nm and 850 nm infrared lasers as the addressing and imaging light source and adjusts the beam and optical path with appropriate parameters.Results and Discussions The upconversion emission spectra of NYF@NGF@NYF are measured[Fig.3(b)].After integrating the emission spectrum in the visible range(500-700 nm),it can be concluded that contrast is I1550+850/(I1550+I850)=28.69,where I1550+I850,I1550,and I850 are the emission intensity under co-excitation of 1550 nm and 850 nm lasers,under excitation of 1550 nm laser,and under excitation of 850 nm laser respectively.With self-made display materials and the self-built static volumetric display system,a variety of 3D images can be demonstrated at a refresh rate of 40 Hz,and the images are clear and bright(Fig.7).The maximum luminous power of a single point measured by the power meter can reach 0.5 mW,the theoretical maximum resolution can be 30×1024×768,and the number of voxels is close to 23 million.Conclusions We report a two-beam scanning 3D imaging system based on the dual-frequency upconversion luminescence mechanism of rare earth ions.The DLP and scanning galvanometer in the optical path are controlled by the computer to build a 3D dynamic model in the liquid medium.The images presented by the system feature stability,high resolution,fast scanning speed,and maximum voxels of 23 million,without observation angle limitations.The various parts of the system such as the light source,the light path,and the display medium are independent and can be quickly replaced and flexibly adjusted to adapt to the excitation properties of different materials.The material adopted for the display is a cyclohexane solution of the core-shell structure NYF@NGF@NYF nanocrystals,which has great potential for large-scale imaging.The system has certain reference significance for the development of volumetric 3D display and provides support for the preliminary research on 3D display capability of display media such as TSTF materials.Meanwhile,this display system is characterized by convenient building and obvious display effect,without the requirement for high material properties.It assists with the preliminary research on up-conversion materials in 3D display and serves as references for exploring largesize 3D volume display technology.
作者 韩东成 杨世植 赵强 张亮亮 邓燕 Han Dongcheng;Yang Shizhi;Zhao Qiang;Zhang Liangliang;Deng Yan(Key Laboratory of Atmospheric Optics,Anhui Institute of Optics and Fine Mechanics,Chinese Academy of Sciences,Hefei 230031,Anhui,China;Science Island Branch,Graduate School,University of Science and Technology of China,Hefei 230026,Anhui,China;Advanced Laser Technology Laboratory of Anhui Province,Hefei 230037,Anhui,China;School of Environment and Energy Engineering,Anhui Jianzhu University,Hefei 230601,Anhui,China;Anhui Easpeed Technology Co.,Ltd.,Hefei 230088,Anhui,China)
出处 《光学学报》 EI CAS CSCD 北大核心 2024年第8期52-62,共11页 Acta Optica Sinica
基金 国家自然科学基金(11704003) 安徽省高校协同创新项目(GXXT-2022-085) 安徽省教育厅高校自然科学研究项目(2022AH050233) 安徽省重点研究与开发计划(2020b05050006)。
关键词 体三维显示 双步双频上转换 NaYF4纳米晶 数字微镜显示器 volumetric 3D display two-step two-frequency upconversion NaYF4 nanocrystals digital micromirror display
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部