摘要 阿根廷基什内尔总统水电站装设5台额定功率为190 MW的混流式水轮发电机组,在电力系统中承担发电、调峰和调相功能,是“一带一路”在南美地区的标志性工程。国外咨询工程师对水轮发电机的频率变化范围、额定电压和槽电流、短路比和纵轴同步电抗、冷却方式、消防方案等技术参数和结构要求与国内标准和习惯不同,通过比较分析相关国内外标准规范和类似水电站发电机参数水平,对水轮发电机性能参数和结构特点进行总结和概括,供类似水电站发电机选型和设计参考。 The Nestor Kirchner Presidential hydroelectric power station in Argentina is equipped with five Francis turbine-generator units,each rated at 190MW.These units play crucial roles in power generation,peak regulation,and phase modulation in the power system.It is a landmark project for the Belt and Road Initiative in South America.The foreign consulting engineers have different technical parameters and structural requirements for the frequency variation range,rated voltage,slot current,short-circuit ratio,direct axis synchronous reactance,cooling methods,and fire protection schemes of the hydraulic turbine generators compared to domestic standards and practices.By comparing and analyzing relevant domestic and foreign standards and similar hydroelectric power station generator parameters,this paper summarizes and generalizes the performance parameters and structural characteristics of turbine generators,providing a reference for the selection and design of similar hydroelectric power station generators.
作者 宋均琪 陈阳 SONG Junqi;CHEN Yang(China Water Resources Beifang Investigation,Design and Research Co.Ltd.,Tianjin,300222)
出处 《水利水电工程设计》 2024年第2期52-55,共4页 Design of Water Resources & Hydroelectric Engineering
关键词 总统水电站 水轮发电机 槽电流 短路比 CO_(2)消防 Nestor Kirchner Presidential hydroelectric power station hydraulic turbine generator slot current short-circuit ratio CO_(2)fire protection
  • 相关文献

参考文献7

二级参考文献5

共引文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部