核电厂消防水管道喷头腐蚀堵塞原因分析

Analysis of Corrosion and Blockage for Sprinkler of Fire Water Pipelines in Nuclear Power Plants
下载PDF
导出
摘要 某核电厂反应堆厂房内水喷雾灭火系统部分喷头发生腐蚀、腐蚀产物堵塞喷头问题。本文从腐蚀环境、材质等方面分析了腐蚀失效发生的原因,并提出相关建议,避免类似失效事件的再次发生。 Some nozzles of the water spray fire protection systems in the reactor building of a nuclear power plant were corroded,and the nozzles were blocked by corrosion products.Through the corrosion environment and material analysis,we reach the pipe failure causes;make some specific suggestions to prevent similar incidents failure.
作者 吴昉赟 黄超 黄铠 李世伟 周澄 刘洪群 WU Fang-yun;HUANG Chao;HUANG Kai;LI Shi-wei;ZHOU Cheng;LIU Hong-qun(CNNC Nuclear Power Operations Management Co.,Ltd.Jiaxing 314000,China;CNNP Operation Maintenance technology Co.,Ltd.Hangzhou 310000,China;Suzhou Nuclear Power Research Institute,Suzhou 215004,China)
出处 《全面腐蚀控制》 2024年第6期185-187,共3页 Total Corrosion Control
关键词 消防水管道 水喷雾灭火系统 水雾喷头 腐蚀 fire water pipeline spray fire protection systems spray nozzle corrosion