摘要 采用芬顿+混凝、紫外(UV)/H_(2)O_(2)、臭氧+混凝3种氧化体系对印染废水二沉池出水进行深度处理,并对处理效果进行定量分析,结果表明,3种氧化体系均可将二沉池出水COD的质量浓度降至30 mg/L以下;芬顿+混凝的废水处理费用最低,为3.25元/t;UV/H2O2对污染物的去除能力最强,出水COD和TOC的质量浓度分别为19.9和2 mg/L;臭氧+混凝对色度的去除效果最佳,出水色度仅为5.6度。经综合考虑,芬顿+混凝体系更加适宜处理该废水。 Three oxidation systems:Fenton+coagulation,ultraviolet(UV)/H_(2)O_(2) and ozone+coagulation,were used for advanced treatment of secondary sedimentation tank effluent of printing and dyeing wastewater,and the treatment effect was quantitatively analyzed.The results showed that,the above three oxidation systems could reduce the mass concentration of COD in secondary sedimentation tank effluent to below 30 mg/L,and the wastewater treatment cost of Fenton+coagulation was the lowest,which was 3.25 yuan/t.UV/H_(2)O_(2) had the strongest pollutant-removing ability,the mass concentrations of COD and TOC were 19.9 and 2 mg/L respectively.ozone+coagulation obtained the best colority-removing effect,and the colority of the effluent water was only 5.6 degree.According to the comprehensive consideration,Fenton+coagulation system was more suitable for the said kind of wastewater treatment.
作者 田敏慧 赵楠楠 许子聪 李海松 TIAN Minhui;ZHAO Nannan;XU Zicong;LI Haisong(Zhihe Environmental Science and Technology,Co.,Ltd.,Zhengzhou 450001,China;School of Ecology and Environment,Zhengzhou University,Zhengzhou 450001,China)
出处 《工业用水与废水》 CAS 2024年第3期25-29,共5页 Industrial Water & Wastewater
基金 国家自然科学基金面上项目(52370088) 河南省重点研发专项(231111320100)。
关键词 芬顿 UV/H_(2)O_(2) 混凝 臭氧氧化 深度处理 污水回用 高级氧化 Fenton UV/H_(2)O_(2) coagulation ozone oxidation advanced treatment wastewater reuse advanced oxidation
  • 相关文献

参考文献13

二级参考文献114

共引文献51

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部