期刊文献+

废碱氧化系统运行异常分析及防范措施

ANALYSIS ON ABNORMAL OPERATION OF SPENT CAUSTIC OXIDATION UNIT AND THE PREVENTIVE MEASURES
下载PDF
导出
摘要 阐述了乙烯装置废碱氧化系统的波动情况,对碱洗塔操作参数、碱洗塔各段碱液和废碱进行了取样分析。基于取样结果分析了废碱氧化系统波动的原因,判断波动主要来源于220 kt/a乙烯装置废碱中的黑色固体颗粒,并基于此提出了相应的防范措施。 This article elaborates on the fluctuation of spent caustic oxidation unit in ethylene plant,and analyzes the operating parameters of caustic wash tower and the sampling of caustic liquor and spent caustic in each section of the caustic wash tower.Based on the sampling results,the reasons for the fluctuation of spent caustic oxidation unit were analyzed,and it was determined that the fluctuation mainly came from the black solid particles in the spent caustic of the 220 kt/a ethylene plant.Based on this,some corresponding preventive measures were proposed.
作者 坎晓杰 田晓兰 万晓明 陈权 张丽霞 Kan Xiaojie;Tian Xiaolan;Wan Xiaoming;Chen Quan;Zhang Lixia(PetroChina Dushanzi Petrochemical Company,Dushanzi,Xinjiang,P.C.833699)
出处 《乙烯工业》 CAS 2024年第2期18-21,I0001,共5页 Ethylene Industry
关键词 废碱氧化 床层温度 固体颗粒 spent caustic oxidation bed temperature solid particle
  • 相关文献

参考文献2

二级参考文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部