摘要
使用EFIT程序设计了HL-3装置雪花偏滤器位形,研究了雪花位形对HL-3装置极向场(PF)线圈电流变化的敏感性。研究发现:当PF线圈电流变化达1%时,标准雪花偏滤器转变为雪花加位形或是雪花减位形;当PF线圈电流变化超过8.8%时,雪花减位形在大偏离度下能够获得平衡位形,而雪花加位形难以获得收敛结果。
The configuration of the HL-3 snowflake divertor by using the EFIT program was designed,and the sensitivity of the snowflake configuration of HL-3 tokamak on the individual lower poloidal field(PF)coil current was studied.It was found that when the individual lower PF coil current only changes by 1%,the standard snowflake divertor immediately changes to a snowflake plus configuration or snowflake minus configuration,and when the individual lower PF current changes above 8.8%,the snowflake minus configuration can reach a equilibrium configuration with a large deviation,while the convergence result is difficult to be obtained under the snowflake plus configuration.
作者
李世敏
王占辉
王志斌
黄波
罗一鸣
吴雪科
付彩龙
昆仑集成模拟设计组
LI Shi-min;WANG Zhan-hui;WANG Zhi-bin;HUANG Bo;LUO Yi-ming;WU Xue-ke;FU Cai-long;Kunlun integrated simulation and design group(Southwestern Institute of Physics,Chengdu 610041;Franco-Chinese Institute of Nuclear Energy,SUN YAT-SEN University,Zhuhai 519082)
出处
《核聚变与等离子体物理》
CAS
CSCD
北大核心
2024年第2期236-241,共6页
Nuclear Fusion and Plasma Physics
基金
国家磁约束核聚变能发展研究专项(2018YFE0303102,2017YFE0302100)
国家自然科学基金(11805158,11875234,12047576)
四川省科技创新人才项目(2022JDRC0014)
国家自然科学基金重点研发项目(U1867222)
四川省青年科技创新研究团队项目(2020JDTD0030)。