500 kV变电站直流融冰装置参数设计标准差异对比研究 被引量:1

Comparative Study on Differences between Standards of Parameter Design for DC Ice-melting Device in 500 kV Substation
下载PDF
导出
摘要 针对变电站直流融冰装置参数工程设计问题,比较和分析不同标准、规范关于融冰电流计算公式的差异,以某500 kV变电站实际工程直流融冰装置参数设计为例,按照不同计算公式给出了最小融冰电流、最大融冰电流、1 h融冰电流、直流融冰压降、直流融冰装置容量等参数计算结果;通过对比分析给出实际工程中融冰装置参数设计公式选用的建议。 Aiming at the engineering design of DC ice-melting device parameters in substations,the differences between calculation formulas of ice-melting current in different standards and specifications are compared and analyzed.Taking the parameter design of DC ice-melting device in a 500 kV substation for example,the calculation results of minimum ice-melting current,maximum ice-melting current,one-hour ice-melting current,DC ice-melting voltage drop,DC ice-melting device capacity and other parameters are given.Suggestions for the selection of parameter design formula of ice-melting device in practical engineering are proposed.
作者 吴小刚 何锐 WU Xiaogang;HE Rui(China Energy Engineering Group Guangdong Electric Power Design Institute Co.,Ltd.,Guangzhou 510663,Guangdong,China;School of Electrical Engineering and Electronic Information,Xihua University,Chengdu 610039,Sichuan,China)
出处 《四川电力技术》 2024年第3期72-75,共4页 Sichuan Electric Power Technology
关键词 直流融冰装置 融冰电流 融冰电压 规范差异 DC ice-melting device ice-melting current ice-melting voltage specification differences