摘要
为了掌握地源热泵地埋侧土壤的吸热放热特性,以某高校地源热泵供暖供冷为例对地埋侧土壤的吸热放热特性进行了研究,对6口地埋井在纵向按照每10米一个测点进行了温度监测,经过1a的监测数据分析得出,热泵系统一年内向地下的净排热量为10560.1GJ,热不平衡率为61.8%,存在热累积现象。分析了岩土体在供暖季、过渡季、制冷季的温度变化情况,换热区域地层平均温度升幅在1.65-2.24℃之间,平均累计上升1.89℃,为该地区同类项目的开发具有一定的借鉴作用。
In order to understand the heat absorption and release characteristics of the soil on the ground side of a ground source heat pump,this article takes the heating and cooling supply of a certain university's ground source heat pump as an example to study the heat absorption and release characteristics of the soil on the ground side.Six underground wells were monitored longitudinally at a measurement point every 10 meters.After a year of monitoring data analysis,it was found that the net heat output of the heat pump system to the ground within a year was 10560.1GJ,and the thermal imbalance rate was 61.8%,There is a phenomenon of heat accumulation.Analyzed the temperature changes of rock and soil during the heating season,transition season,and cooling season.The average temperature rise of the formation in the heat exchange area is between 1.65 and 2.24℃,with an average cumulative increase of 1.89℃.This provides a certain reference for the development of similar projects in the region.
作者
刘俊青
吴晓轩
刘彪
牛晓洁
张昌建
Liu Junqing;Wu Xiaoxuan;Liu Biao;Niu Xiaojie;Zhang Changjian(Hydrogeology Bureau of China Coal Geology Administration,Handan,056000;School of Energy and Environmental Engineering,Hebei University of Engineering,Handan,056000)
出处
《制冷与空调(四川)》
2024年第3期385-393,共9页
Refrigeration and Air Conditioning
基金
河北省重大科技成果转化项目“矿山余热废热资源化利用成装备研发与产业化”(项目编号21284102Z)
河北省重点研发计划项目“太阳能,地热能、相变能多能互补(电、热、冷系统)关键技术与装备研发与示范”(项目编号236Z4310G)
河北省创新能力提升计划项目“河北省暖通空调后补助经费”(项目编号22567691H)。
关键词
地源热泵
地温监测
热累积
吸热放热特性
Ground source heat pump
Ground temperature monitoring
Heat accumulation
Heat absorption and release characteristics