摘要 分析地下水人工回灌过程中颗粒的沉积特征以及影响沉积的多种因素,搭建地下水回灌物理试验系统和颗粒沉积过程CT扫描检测系统,在此基础上构建与地下水回灌试验系统内砂柱对应的数值模型,用于分析回灌水温度、回灌颗粒电荷和回灌水头对颗粒沉积的影响权重,从而将回灌水温度和回灌颗粒电荷与回灌水头纳入同一评价体系中。结果表明:对于地下水人工回灌过程中颗粒沉积来说,回灌水头影响最大,回灌水温度的影响不可忽视,在地下水源热泵等水温变化幅度较大的工程场景中,回灌水温度的影响超过了回灌水头,回灌颗粒电荷的影响较小。研究成果拓宽了对地下水回灌颗粒堵塞和颗粒沉积影响因素的认知,有利于在地下水回灌工程的设计和运行过程中合理规避颗粒堵塞的影响。 Artificial recharge of groundwater is a technology that injects excess surface water,rain flood or reclaimed water into the ground through surface infiltration or artificial recharge wells,so as to effectively recharge groundwater and raise the groundwater level.The physical clogging dominated by particle clogging is the main factor restricting the large-scale popularization and application of groundwater artificial recharge project.The particle deposition process in the pores of the media controls the particle clogging phenomenon of the whole media.At present,the research on the internal relationship,mutual transformation and cross-scale coupling between the two processes is limited.The movement and deposition of particles in the pores of the media are the microscopic mechanism of particle clogging.The important factor affecting the movement state of particles in the pores of the media is the pore water flow field.The recharge head is the decisive factor to determine the flow velocity and flow field distribution.The temperature will change the dynamic viscosity and density of the water,which will affect the flow field,change the fluid drag force on the particles and affect the particle deposition.The pH and ionic strength of recharge water affect the particle deposition by affecting the charge of the particles in the water.A physical experimental system of particle clogging in one-dimensional sand column groundwater recharge with fixed head was built,and two media were used for comparative experiments.Combined with physical experiments and Computed Tomography,a numerical model that can describe the particle deposition process in the pores of porous media is constructed,and the numerical model is corrected and verified by physical experiment data and CT scan results.The recharge temperature is selected as the thermodynamic factor,the recharge particle charge is selected as the electrochemical factor,and the recharge head is selected as the engineering factor,and the three are included in one groundwater recharge particle clogging evaluation system.The numerical simulation of multiphysical scenarios withμm-level accuracy was carried out to research the effects of hydraulic factors,thermodynamic factors,and electrochemical factors on the deposition of groundwater recharge particles.According to the combination of the upper limit,the lower limit and the intermediate value of each influencing factor,multiple physical scenarios are set up.The influence weight value of the recharge head on the particle deposition of the two media is 0.1443,the influence weight value of the recharge temperature is 0.6488,and the weight value of the recharge particle charge is 0.2069.There are many data fluctuations in the numerical simulation process,which indicates that the internal flow field and particle motion process of the media are extremely complex and changeable,and a theoretical explanation is proposed.The recharge head is used as a control group to analyze the influence of thermodynamic factors and electrochemical factors on particle clogging and particle deposition in groundwater recharge compared with conventional engineering factors.The range of values is small.In the practice of groundwater artificial recharge engineering,the engineering factors such as recharge head and particle concentration of recharge water still have the greatest impact on particle clogging.The recharge temperature has the highest weight only in engineering scenarios involving extreme water temperature recharge such as groundwater source heat pump.In the case of large variation of recharge temperature,the highest weight factor affecting particle deposition in quartz sand media and glass bead media is recharge temperature,followed by recharge head,and recharge particle charge is the factor with the lowest weight.In the engineering scenarios involving extreme recharge temperature such as ground source heat pump,it is necessary to consider the recharge temperature as an important factor affecting the groundwater recharge clogging.At the same time,the influence of water temperature on the occurrence and development of particle clogging can not be ignored in ordinary projects that do not involve extreme recharge temperature.The influence of electrochemical factors on particle deposition and particle clogging in the process of artificial recharge of groundwater is low.When considering the physical clogging of groundwater recharge such as particle clogging,the electrochemical factors such as ionic strength and pH of recharge water can be selectively ignored.
作者 王诏楷 束龙仓 刘佩贵 董宁澎 顾娜 张世杰 WANG Zhaokai;SHU Longcang;LIU Peigui;DONG Ningpeng;GU Na;ZHANG Shijie(Anhui and Ministry of Water Resources Huaihe River Institute of Hydraulic Research,Hefei 230088,China;Key Laboratory of Water Conservancy and Water Resources of Anhui Province,Bengbu 233000,China;College of Hydrology and Water Resources,Hohai University,Nanjing 210098,China;College of Civil Engineering,Hefei University of Technology,Hefei 230009,China;State Key Laboratory of Simulation and Regulation of Water Cycle in River Basin,China Institute of Water Resources and Hydropower Research,Beijing 100038,China;Anhui Province Hydrology Bureau,Hefei 230022,China)
出处 《南水北调与水利科技(中英文)》 CAS CSCD 北大核心 2024年第3期502-511,共10页 South-to-North Water Transfers and Water Science & Technology
基金 国家重点研发计划项目(2021YFC3200500) 安徽省(水利部淮河水利委员会)水利科学研究院自主研发项目(KY202208) 安徽省自然科学基金资助项目(2308085US04 2208085US21)
关键词 颗粒沉积 人工回灌 数值模拟 沉积特征 影响因素 particle deposition groundwater artificial recharge numberical simulation depositional characteristics influence factor