期刊文献+

电感耦合等离子体原子发射光谱法(ICP-AES)测定硅铝微粉中铍的含量

Determination on Beryllium Content in Silicon-aluminum Powder by Inductively Coupled Plasma Atomic Emission Spectrometry(ICP-AES)
下载PDF
导出
摘要 采用电感耦合等离子体发射光谱法对硅铝微粉中铍元素的含量进行测定。本文采用氢氧化钠高温条件下对硅铝微粉样品进行熔融,确定了氢氧化钠的用量及熔融时间,确立了最佳试验条件,铝基体和硅基体对测定结果无干扰,但碱熔法带入了大量的钠盐,故采用基体匹配标准曲线法,标准曲线的线性相关系数为0.9999;方法的精密度较好,相对标准偏差(n=11)小于3.00%;方法的灵敏度较高,检出限为0.02116μg/g;加标回收率为99.4%~103.67%。方法适用于硅铝微粉中铍元素含量范围为2.00~300.00μg/g的测定。 Inductively coupled plasma emission spectroscopy is adopted for the determination of beryllium elements in silicon-aluminum powder.Melting of silicon-aluminum powder sample was carried out by using sodium hydroxide under high-temperature condition,it confirmed the dosage and melting time of sodium hydroxide,the best test conditions,it has no interference with the testing results from the aluminum matrix and silicon matrix;because of using the alkali fusion method,a lot of sodium salt brought in,the matrix matching standard curve method as adopted,the linearly dependent coefficient of the standard curve is 0.9999;the method precision is better,the relative standard deviation(n=11)is less than 3.00%;the method sensitivity is higher,the detection limit is 0.02116μg/g,the recovery rate with addition of standard matters is 99.4%~103.67%.The method is appropriate for the determination of beryllium content in silicon-aluminum powder,which has the range of 2.00~300.00μg/g.
作者 杨艳辉 廖仕英 蒋娴芳 陈怡君 张杰 陈格 YANG Yanhui;LIAO Shiying;JIANG Xianfang;CHEN Yijun;ZHANG Jie;CHEN Ge(Tianqi Lithium Co.,Ltd.,Shehong,Sichuan 629200,China;Lithium Resources and Lithium Materials Key Laboratory of Sichuan Province,Shehong,Sichuan 629200,China)
出处 《云南冶金》 2024年第3期155-160,170,共7页 Yunnan Metallurgy
关键词 硅铝微粉 电感耦合等离子发射光谱仪 碱熔 silicon-aluminum powder beryllium inductively coupled plasma emission spectroscopy alkali fusion
  • 相关文献

参考文献9

二级参考文献66

共引文献87

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部