摘要 总结了目前数据中心冷却系统几种常见形式,结合具体案例分析了近几年新兴的液冷系统几种常见形式和技术特点,针对韶关、贵安新区、庆阳三个典型地区数据中心应用的气候资源条件和能源禀赋以及适用的冷却方案做了分析探讨,得出上述三地区数据中心冷却系统的推荐技术方案。 This paper summarizes several common forms of data center cooling system,analyzes several common forms and technical characteristics of emerging liquid cooling system in recent years with specific cases,analyzes and discusses the climate resource conditions and energy endowment of data center application in Shaoguan,Guian New Area and Qingyang three typical regions and the applicable cooling scheme,and draws the recommended technical solution of data center cooling system in the above three regions.
作者 熊曙 张铎 周慧文 Xiong Shu;Zhang Duo;Zhou Huiwen(China Energy Engineering Group Equipment Co.,Ltd.,Bejing 100044,China;Hangzhou Huadian H uayuan Environment Engineering Co.,Ltd.,Hangzhou 310000,Zhejiang,China)
出处 《电站辅机》 2024年第2期21-26,共6页 Power Station Auxiliary Equipment
关键词 数据中心 冷却系统 液冷系统 气候资源 能源禀赋 Data center cooling system liquid cooling system climate resources energy endowment