期刊文献+

德国化工企业低压配电设计特点

Characteristics of Low-voltage Distribution Design of German Chemical nterprises
下载PDF
导出
摘要 介绍德国化工企业低压配电设计的一些实践做法和特点,包括采用中性点集中一点接地的交流低压配电系统、采用“N+1”配置的变压器-低压单母线分段主接线方案等,并与我国工程设计中的习惯做法进行对比与分析。 Some practices and characteristics of low-voltage distribution design of German chemical enterprises are introduced,including the use of an AC low-voltage distribution system with centralized neutral point grounding,and transformer-low-voltage single-busbar segmented main wiring scheme with an"N+1"configuration,and the customary practices in China's engineering design are compared and analyzed.
作者 魏民 WEI Min(Lianyungang Worley Engineering Co.,Ltd.,Shanghai Branch,Shanghai 201101,China)
出处 《建筑电气》 2024年第6期21-25,共5页 Building Electricity
关键词 德国化工企业 低压配电设计 IEC标准 接地中心柜 熔断器 低压电机综合保护器 变频器选择 配电间活动地板 German chemical enterprises low-voltage distribution design IEC standard grounding gcenter cabinet fuses low-voltage motor integrated protector Variable Frequency Drive(VFD)selection movable floor for distribution room