摘要 本文研究了输电线路故障时刻行波的传播与继电保护动作特征的配合问题,将继电保护动作规律考虑到输电线路故障发展的过程中,从理论上研究故障行波的产生及传播与继电保护动作过程之间的时序关系,制定有效行波提取算法。采用PSCAD仿真软件对110 kV输电线路继电保护建模,分析继电保护动作规律对地电位双端行波定位算法的影响。结果表明,继电保护装置的动作时间远大于行波传递时间,对行波定位几乎没有影响。 The coordination between the propagation of traveling waves during transmission line fault and the characteristics of relay protection actions are studied in this paper.Considering the action law of relay protection in the process of transmission line fault development,the temporal relationship between the generation and propagation of fault traveling waves and the action process of relay protection are theoretically studied,and an effective traveling wave extraction algorithm is developed.PSCAD simulation software is used to build the relay protection model of 110kV transmission line,and the influence of relay protection action rules on the ground potential dual terminal traveling wave positioning algorithm is analyzed.The results show that the action time of relay protection device is much longer than the transmission time of traveling wave,so that it has almost no effect on the traveling wave localization.
作者 李盛东 刘英龙 LI Shengdongg;LIU Yinglong(Electric Power Research Institute of Guangxi Power Grid Co.,Ltd.,Guangxi Nanning 530023,China;Beihai Power Supply Bureau of Guangxi Power Grid Co.,Ltd.,Guangxi Beihai 536000,China;Nanning Power Supply Bureau of Guangxi Power Grid Co.,Ltd.,Guangxi Nanning 530023,China)
出处 《广西电力》 2023年第6期81-87,共7页 Guangxi Electric Power
基金 广西电网有限责任公司科技项目(GXKYXM20222208) 广西人才与基地项目(AD22080006)。
关键词 电磁感应 传感器 非接触式测量 分布式行波监测 行波采集 electromagnetic induction sensor non-contact measurement distributed traveling wave monitoring,Traveling waveacquisition
  • 相关文献

参考文献10

二级参考文献160

共引文献250

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部