期刊文献+

油田集输站库防爆区域的归集与设备选型

Collection and Equipment Selection of Explosion-proof Areas in Oil Field Gathering and Transportation Stations
下载PDF
导出
摘要 集输站库作为油田原油、天然气的中转、贮存、沉降等重要处理场所,具有较高的爆炸危险性,采用防爆电气设备是首选预防措施,根据最新调研情况,80%的站库都存在防爆选型不合理的问题,造成此问题的原因是防爆区域划分不明确,本文论述了集输站库的防爆区域的划分方法和防爆电气的选型原则,并提出几点粗浅建议。 As an important treatment place for the transfer,storage and sedimentation of oil and natural gas,gathering station depot has a high explosion risk.The use of explosion-proof electrical equipment is the preferred preventive measure.According to the latest research,80% of the station depot has the problem of unreasonable explosion-proof selection,which is caused by the unclear division of explosion-proof area.This paper discusses the division method of explosion-proof area of gathering station and the selection principle of explosion-proof electric,and puts forward some suggestions.
作者 乍靖榆 王亭沂 赵峰 杨向莲 张瑾 Zha Jingyu;Wang Tingyi;Zhao Feng;Yang Xianglian;Zhang Jin(Technology Inspection Center,Shengli Oilfi eld,SINOPEC,Shandong 257000;Safety Environmental Protection and Quality Management Department,Shengli Oilfi eld Branch,SINOPEC,Shandong 257000)
出处 《当代化工研究》 CAS 2024年第12期187-190,共4页 Modern Chemical Research
基金 中石化科技项目“防爆电气系统检验监督体系研究”(项目编号:722061)。
关键词 危险区域 设备选型 释放源 释放速率 hazardous areas equipment selection release source release rate
  • 相关文献

参考文献5

二级参考文献18

  • 1GB50058-92.爆炸和火灾危险环境电力装置设计规范[S].[S].,..
  • 2爆炸性气体环境用电气设备第14部分:危险场所分类(GB3836.14-2000).
  • 3石油设施电气装置场所分类(SY/T0025-95).
  • 4GB50183-2004.石油天然气工程设计防火规范[S].[S].,..
  • 5GB50058-92.爆炸和火灾危险环境电力装置设计规范.[S].,..
  • 6GB50057-94.建筑物防雷设计规范[S].[S].,2000..
  • 7GB50054-95.低压配电设计规范[S].[S].,..
  • 8GB50160-1992 石油化工企业设计防火规范[S].1999
  • 9SY0025-95,石油设施电气装置场所分类[S].
  • 10谢承鑫,王立昌,刘淑琴,等.工厂常用电气设备手册[M].北京:水利电力出版社,1988.