以3种不同的MHP-BIPV/T系统为研究对象,研究了2023年1月5日3组系统的光电、光热和综合效率,结果表明:在室外平均温度为0.7℃的天气下,透光-吸热蓝膜MHP-BIPV/T系统、透光MHP-BIPV/T系统、满布微热管MHP-BIPV/T系统的平均电效率可达到13%、13.1%、10.6%,平均综合效率可达到43.9%、65.2%、80%,满布微热管的MHP-BIPV/T系统的综合性能好于透光-吸热蓝膜MHP-BIPV/T系统和透光MHP-BIPV/T系统;3种系统的平均温度均在17.9℃,可以满足基本供暖需求。
The photovoltaic,photothermal and integrated efficiencies of three groups of systems on January 5,2023 were studied with three different MHP-BIPV/T systems,and the results showed that in the weather with an average outdoor temperature of 0.7°C,the transmissive-heat-absorbent blue-film MHP-BIPV/T system,the transmissive MHP-BIPV/T system,and the microtubule-full MHP-BIPV/T system with an average electric efficiency can reach 13%,13.1%and 10.6%,and the average comprehensive efficiency can reach 43.9%,65.2%and 80%,and the comprehensive performance of MHP-BIPV/T system full of micro heat pipes is better than that of light-transmitting-heat-absorbing blue-film MHP-BIPV/T system and light-transmitting MHP-BIPV/T system;the average temperatures of the three systems are over 17.9°C and can meet the basic heating demand.